{"id":309,"date":"2026-02-07T08:29:00","date_gmt":"2026-02-07T00:29:00","guid":{"rendered":"https:\/\/www.han-sphere.com\/?p=309"},"modified":"2026-03-02T22:57:44","modified_gmt":"2026-03-02T14:57:44","slug":"hdi-microvias-blind-buried-via-design","status":"publish","type":"post","link":"https:\/\/www.han-sphere.com\/es\/blog\/news\/hdi-microvias-blind-buried-via-design\/","title":{"rendered":"Microvias, Blind and Buried Vias in HDI PCB Design"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Vias are the foundation of HDI PCB technology. Unlike conventional through-hole vias, <a href=\"https:\/\/www.han-sphere.com\/hdi-pcb\/\">HDI PCBs <\/a>rely on <strong>microvias, blind vias, and buried vias<\/strong> to achieve ultra-high routing density, improved signal integrity, and compact board layouts.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This article explains <strong>how to design microvias, blind vias, and buried vias in HDI PCBs<\/strong>, including design rules, reliability considerations, and manufacturing constraints.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\ud83d\udd17 <em>Part of the HDI PCB Design Series<\/em><br><strong>HDI PCB Design: <a href=\"https:\/\/www.han-sphere.com\/blog\/news\/hdi-pcb-design-technology-overview\/\">Technology<\/a>, <a href=\"https:\/\/www.han-sphere.com\/blog\/news\/hdi-pcb-stackup-design-strategies\/\">Stackup<\/a>, <a href=\"https:\/\/www.han-sphere.com\/blog\/news\/hdi-pcb-routing-bga-fanout-techniques\/\">Routing<\/a>, and <a href=\"https:\/\/www.han-sphere.com\/blog\/news\/hdi-pcb-manufacturing-yield-optimization\/\">Manufacturing<\/a><\/strong><\/p>\n<\/blockquote>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"411\" src=\"http:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/02\/HDI-PCB-Design-4.jpg\" alt=\"HDI PCB Design\" class=\"wp-image-310\" srcset=\"https:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/02\/HDI-PCB-Design-4.jpg 600w, https:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/02\/HDI-PCB-Design-4-300x206.jpg 300w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\">What Are Microvias?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Microvias are laser-drilled vias, typically:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Diameter \u2264 150 \u03bcm<\/li>\n\n\n\n<li>Depth \u2264 1 layer<\/li>\n\n\n\n<li>Used to connect adjacent layers<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">They dramatically reduce via parasitics and free routing space.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Blind Vias and Buried Vias Explained<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Blind Vias<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Connect outer layers to inner layers<\/li>\n\n\n\n<li>Do not pass through the entire board<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Buried Vias<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Connect inner layers only<\/li>\n\n\n\n<li>Invisible from the surface<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Both are created using <strong>sequential lamination<\/strong>.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Why HDI Designs Depend on Microvias<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Microvias enable:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Fine-pitch BGA fanout<\/li>\n\n\n\n<li>Reduced via stubs<\/li>\n\n\n\n<li>Better high-speed signal integrity<\/li>\n\n\n\n<li>Smaller board size<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">For BGA pitches \u2264 0.8 mm, microvias are often mandatory.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Microvia Design Rules and Best Practices<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Aspect Ratio Guidelines<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Recommended microvia aspect ratio \u2264 1:1<\/li>\n\n\n\n<li>Shallower vias improve plating reliability<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">Stacked vs Staggered Microvias<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Stacked Microvias<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Higher density<\/li>\n\n\n\n<li>Higher cost and reliability risk<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Staggered Microvias<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Better reliability<\/li>\n\n\n\n<li>Preferred for most designs<\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">Staggered microvias are generally recommended unless density demands stacking.<\/p>\n<\/blockquote>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">Via-in-Pad Design<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Via-in-pad is common in HDI designs but requires:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Copper filling<\/li>\n\n\n\n<li>Proper planarization<\/li>\n\n\n\n<li>Tight process control<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Poor via filling leads to solder voids and reliability issues.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"443\" src=\"http:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/02\/HDI-PCB-Design-6.jpg\" alt=\"HDI PCB Design\" class=\"wp-image-312\" srcset=\"https:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/02\/HDI-PCB-Design-6.jpg 600w, https:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/02\/HDI-PCB-Design-6-300x222.jpg 300w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\">Electrical Performance Considerations<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">HDI via structures reduce:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Parasitic inductance<\/li>\n\n\n\n<li>Signal reflection<\/li>\n\n\n\n<li>Crosstalk<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">However, poor via geometry can negate these benefits.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Best practices:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Minimize via count<\/li>\n\n\n\n<li>Keep via transitions short<\/li>\n\n\n\n<li>Avoid unnecessary stacked structures<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Reliability Risks in HDI Via Structures<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Common failure modes include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Copper cracking in stacked microvias<\/li>\n\n\n\n<li>Incomplete via fill<\/li>\n\n\n\n<li>Delamination during thermal cycling<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Reliability risk increases with:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Excessive stacking<\/li>\n\n\n\n<li>High aspect ratios<\/li>\n\n\n\n<li>Poor material selection<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Manufacturing Constraints and DFM Rules<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">HDI via design must align with fabricator capability.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Key DFM considerations:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Minimum laser via diameter<\/li>\n\n\n\n<li>Maximum stacking levels<\/li>\n\n\n\n<li>Via fill material selection<\/li>\n\n\n\n<li>Registration accuracy<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Early DFM review is essential for yield.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\ud83d\udd17 <em>Manufacturing context:<\/em><br><strong>HDI PCB Manufacturing Process and Yield Optimization<\/strong><\/p>\n<\/blockquote>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">When to Use Blind\/Buried Vias Instead of Through Vias<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Choose blind\/buried vias when:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Routing density is constrained<\/li>\n\n\n\n<li>Signal integrity is critical<\/li>\n\n\n\n<li>Board size must be minimized<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Through vias remain suitable for low-density areas.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Best Practices Summary<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">To design reliable HDI vias:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Use microvias with aspect ratio \u2264 1:1<\/li>\n\n\n\n<li>Prefer staggered over stacked microvias<\/li>\n\n\n\n<li>Apply via-in-pad only with proper filling<\/li>\n\n\n\n<li>Minimize via transitions<\/li>\n\n\n\n<li>Align designs with manufacturer capability<\/li>\n<\/ul>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"395\" src=\"http:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/02\/HDI-PCB-Design-7.jpg\" alt=\"HDI PCB Design\" class=\"wp-image-313\" srcset=\"https:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/02\/HDI-PCB-Design-7.jpg 600w, https:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/02\/HDI-PCB-Design-7-300x198.jpg 300w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\">Conclusion<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Microvias, blind vias, and buried vias are the backbone of HDI PCB design. Proper via structure selection and disciplined design practices are essential to achieve high density, good signal integrity, and long-term reliability.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This article forms the <strong>technical core<\/strong> of the HDI PCB Design cluster.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">FAQ \u2013 HDI Microvias and Via Design<\/h2>\n\n\n\n<div class=\"schema-faq wp-block-yoast-faq-block\"><div class=\"schema-faq-section\" id=\"faq-question-1770222752264\"><strong class=\"schema-faq-question\">Q: <strong>1. What is the difference between a microvia and a blind via?<\/strong><\/strong> <p class=\"schema-faq-answer\">A: A microvia is a type of blind via created by laser drilling, typically connecting only adjacent layers.<\/p> <\/div> <div class=\"schema-faq-section\" id=\"faq-question-1770222766882\"><strong class=\"schema-faq-question\">Q: <strong>2. Are stacked microvias unreliable?<\/strong><\/strong> <p class=\"schema-faq-answer\">A: They can be reliable if manufactured correctly, but they carry higher risk than staggered microvias.<\/p> <\/div> <div class=\"schema-faq-section\" id=\"faq-question-1770222779722\"><strong class=\"schema-faq-question\">Q: <strong>3. When is via-in-pad required?<\/strong><\/strong> <p class=\"schema-faq-answer\">A: Via-in-pad is used for fine-pitch BGAs where escape routing space is limited.<\/p> <\/div> <div class=\"schema-faq-section\" id=\"faq-question-1770222793726\"><strong class=\"schema-faq-question\">Q: <strong>4. Can microvias replace all through-hole vias?<\/strong><\/strong> <p class=\"schema-faq-answer\">A: No. Through vias are still useful for power, ground, and low-density regions.<\/p> <\/div> <div class=\"schema-faq-section\" id=\"faq-question-1770222816556\"><strong class=\"schema-faq-question\">Q: <strong>5. How many microvia stacks are acceptable?<\/strong><\/strong> <p class=\"schema-faq-answer\">A: Most manufacturers recommend limiting stacks to 2 levels for reliability.<\/p> <\/div> <div class=\"schema-faq-section\" id=\"faq-question-1770222835773\"><strong class=\"schema-faq-question\">Q: <strong>6. Do microvias improve signal integrity?<\/strong><\/strong> <p class=\"schema-faq-answer\">A: Yes. Shorter via length reduces parasitic inductance and reflections.<\/p> <\/div> <\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>This summary covers design guidelines for microvias, blind vias, and buried vias in HDI PCBs. It addresses key considerations, including via-in-pad rules, potential reliability risks, and critical manufacturing constraints to ensure robust board fabrication.<\/p>","protected":false},"author":1,"featured_media":311,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":"","footnotes":""},"categories":[4],"tags":[31],"class_list":["post-309","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news","tag-microvias"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Microvias, Blind and Buried Vias in HDI PCB Design - HanSphere<\/title>\n<meta name=\"description\" content=\"Learn how to design microvias, blind vias, and buried vias in HDI PCBs, including via-in-pad rules, reliability risks, and manufacturing constraints.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.han-sphere.com\/es\/blog\/news\/hdi-microvias-blind-buried-via-design\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Microvias, Blind and Buried Vias in HDI PCB Design - HanSphere\" \/>\n<meta property=\"og:description\" content=\"Learn how to design microvias, blind vias, and buried vias in HDI PCBs, including via-in-pad rules, reliability risks, and manufacturing constraints.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.han-sphere.com\/es\/blog\/news\/hdi-microvias-blind-buried-via-design\/\" \/>\n<meta property=\"og:site_name\" content=\"hansphere\" \/>\n<meta property=\"article:published_time\" content=\"2026-02-07T00:29:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-03-02T14:57:44+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/02\/HDI-PCB-Design-5.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"600\" \/>\n\t<meta property=\"og:image:height\" content=\"337\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"hansphere01\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"hansphere01\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":[\"WebPage\",\"FAQPage\"],\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/\",\"url\":\"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/\",\"name\":\"Microvias, Blind and Buried Vias in HDI PCB Design - HanSphere\",\"isPartOf\":{\"@id\":\"https:\/\/www.han-sphere.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/02\/HDI-PCB-Design-5.jpg\",\"datePublished\":\"2026-02-07T00:29:00+00:00\",\"dateModified\":\"2026-03-02T14:57:44+00:00\",\"author\":{\"@id\":\"https:\/\/www.han-sphere.com\/#\/schema\/person\/a8f2356806898d33a9f431801140e422\"},\"description\":\"Learn how to design microvias, blind vias, and buried vias in HDI PCBs, including via-in-pad rules, reliability risks, and manufacturing constraints.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/#breadcrumb\"},\"mainEntity\":[{\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/#faq-question-1770222752264\"},{\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/#faq-question-1770222766882\"},{\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/#faq-question-1770222779722\"},{\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/#faq-question-1770222793726\"},{\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/#faq-question-1770222816556\"},{\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/#faq-question-1770222835773\"}],\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/#primaryimage\",\"url\":\"https:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/02\/HDI-PCB-Design-5.jpg\",\"contentUrl\":\"https:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/02\/HDI-PCB-Design-5.jpg\",\"width\":600,\"height\":337,\"caption\":\"HDI PCB Design\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.han-sphere.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Microvias, Blind and Buried Vias in HDI PCB Design\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.han-sphere.com\/#website\",\"url\":\"https:\/\/www.han-sphere.com\/\",\"name\":\"hansphere\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.han-sphere.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.han-sphere.com\/#\/schema\/person\/a8f2356806898d33a9f431801140e422\",\"name\":\"hansphere01\",\"sameAs\":[\"http:\/\/www.han-sphere.com\/\"],\"url\":\"https:\/\/www.han-sphere.com\/es\/author\/hansphere01\/\"},{\"@type\":\"Question\",\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/#faq-question-1770222752264\",\"position\":1,\"url\":\"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/#faq-question-1770222752264\",\"name\":\"Q: 1. What is the difference between a microvia and a blind via?\",\"answerCount\":1,\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"A: A microvia is a type of blind via created by laser drilling, typically connecting only adjacent layers.\",\"inLanguage\":\"es\"},\"inLanguage\":\"es\"},{\"@type\":\"Question\",\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/#faq-question-1770222766882\",\"position\":2,\"url\":\"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/#faq-question-1770222766882\",\"name\":\"Q: 2. Are stacked microvias unreliable?\",\"answerCount\":1,\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"A: They can be reliable if manufactured correctly, but they carry higher risk than staggered microvias.\",\"inLanguage\":\"es\"},\"inLanguage\":\"es\"},{\"@type\":\"Question\",\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/#faq-question-1770222779722\",\"position\":3,\"url\":\"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/#faq-question-1770222779722\",\"name\":\"Q: 3. When is via-in-pad required?\",\"answerCount\":1,\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"A: Via-in-pad is used for fine-pitch BGAs where escape routing space is limited.\",\"inLanguage\":\"es\"},\"inLanguage\":\"es\"},{\"@type\":\"Question\",\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/#faq-question-1770222793726\",\"position\":4,\"url\":\"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/#faq-question-1770222793726\",\"name\":\"Q: 4. Can microvias replace all through-hole vias?\",\"answerCount\":1,\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"A: No. Through vias are still useful for power, ground, and low-density regions.\",\"inLanguage\":\"es\"},\"inLanguage\":\"es\"},{\"@type\":\"Question\",\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/#faq-question-1770222816556\",\"position\":5,\"url\":\"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/#faq-question-1770222816556\",\"name\":\"Q: 5. How many microvia stacks are acceptable?\",\"answerCount\":1,\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"A: Most manufacturers recommend limiting stacks to 2 levels for reliability.\",\"inLanguage\":\"es\"},\"inLanguage\":\"es\"},{\"@type\":\"Question\",\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/#faq-question-1770222835773\",\"position\":6,\"url\":\"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/#faq-question-1770222835773\",\"name\":\"Q: 6. Do microvias improve signal integrity?\",\"answerCount\":1,\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"A: Yes. Shorter via length reduces parasitic inductance and reflections.\",\"inLanguage\":\"es\"},\"inLanguage\":\"es\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Microvias, Blind and Buried Vias in HDI PCB Design - HanSphere","description":"Learn how to design microvias, blind vias, and buried vias in HDI PCBs, including via-in-pad rules, reliability risks, and manufacturing constraints.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.han-sphere.com\/es\/blog\/news\/hdi-microvias-blind-buried-via-design\/","og_locale":"es_ES","og_type":"article","og_title":"Microvias, Blind and Buried Vias in HDI PCB Design - HanSphere","og_description":"Learn how to design microvias, blind vias, and buried vias in HDI PCBs, including via-in-pad rules, reliability risks, and manufacturing constraints.","og_url":"https:\/\/www.han-sphere.com\/es\/blog\/news\/hdi-microvias-blind-buried-via-design\/","og_site_name":"hansphere","article_published_time":"2026-02-07T00:29:00+00:00","article_modified_time":"2026-03-02T14:57:44+00:00","og_image":[{"width":600,"height":337,"url":"http:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/02\/HDI-PCB-Design-5.jpg","type":"image\/jpeg"}],"author":"hansphere01","twitter_card":"summary_large_image","twitter_misc":{"Escrito por":"hansphere01","Tiempo de lectura":"4 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":["WebPage","FAQPage"],"@id":"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/","url":"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/","name":"Microvias, Blind and Buried Vias in HDI PCB Design - HanSphere","isPartOf":{"@id":"https:\/\/www.han-sphere.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/#primaryimage"},"image":{"@id":"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/#primaryimage"},"thumbnailUrl":"https:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/02\/HDI-PCB-Design-5.jpg","datePublished":"2026-02-07T00:29:00+00:00","dateModified":"2026-03-02T14:57:44+00:00","author":{"@id":"https:\/\/www.han-sphere.com\/#\/schema\/person\/a8f2356806898d33a9f431801140e422"},"description":"Learn how to design microvias, blind vias, and buried vias in HDI PCBs, including via-in-pad rules, reliability risks, and manufacturing constraints.","breadcrumb":{"@id":"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/#breadcrumb"},"mainEntity":[{"@id":"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/#faq-question-1770222752264"},{"@id":"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/#faq-question-1770222766882"},{"@id":"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/#faq-question-1770222779722"},{"@id":"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/#faq-question-1770222793726"},{"@id":"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/#faq-question-1770222816556"},{"@id":"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/#faq-question-1770222835773"}],"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/#primaryimage","url":"https:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/02\/HDI-PCB-Design-5.jpg","contentUrl":"https:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/02\/HDI-PCB-Design-5.jpg","width":600,"height":337,"caption":"HDI PCB Design"},{"@type":"BreadcrumbList","@id":"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.han-sphere.com\/"},{"@type":"ListItem","position":2,"name":"Microvias, Blind and Buried Vias in HDI PCB Design"}]},{"@type":"WebSite","@id":"https:\/\/www.han-sphere.com\/#website","url":"https:\/\/www.han-sphere.com\/","name":"hansphere","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.han-sphere.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Person","@id":"https:\/\/www.han-sphere.com\/#\/schema\/person\/a8f2356806898d33a9f431801140e422","name":"hansphere01","sameAs":["http:\/\/www.han-sphere.com\/"],"url":"https:\/\/www.han-sphere.com\/es\/author\/hansphere01\/"},{"@type":"Question","@id":"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/#faq-question-1770222752264","position":1,"url":"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/#faq-question-1770222752264","name":"Q: 1. What is the difference between a microvia and a blind via?","answerCount":1,"acceptedAnswer":{"@type":"Answer","text":"A: A microvia is a type of blind via created by laser drilling, typically connecting only adjacent layers.","inLanguage":"es"},"inLanguage":"es"},{"@type":"Question","@id":"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/#faq-question-1770222766882","position":2,"url":"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/#faq-question-1770222766882","name":"Q: 2. Are stacked microvias unreliable?","answerCount":1,"acceptedAnswer":{"@type":"Answer","text":"A: They can be reliable if manufactured correctly, but they carry higher risk than staggered microvias.","inLanguage":"es"},"inLanguage":"es"},{"@type":"Question","@id":"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/#faq-question-1770222779722","position":3,"url":"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/#faq-question-1770222779722","name":"Q: 3. When is via-in-pad required?","answerCount":1,"acceptedAnswer":{"@type":"Answer","text":"A: Via-in-pad is used for fine-pitch BGAs where escape routing space is limited.","inLanguage":"es"},"inLanguage":"es"},{"@type":"Question","@id":"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/#faq-question-1770222793726","position":4,"url":"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/#faq-question-1770222793726","name":"Q: 4. Can microvias replace all through-hole vias?","answerCount":1,"acceptedAnswer":{"@type":"Answer","text":"A: No. Through vias are still useful for power, ground, and low-density regions.","inLanguage":"es"},"inLanguage":"es"},{"@type":"Question","@id":"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/#faq-question-1770222816556","position":5,"url":"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/#faq-question-1770222816556","name":"Q: 5. How many microvia stacks are acceptable?","answerCount":1,"acceptedAnswer":{"@type":"Answer","text":"A: Most manufacturers recommend limiting stacks to 2 levels for reliability.","inLanguage":"es"},"inLanguage":"es"},{"@type":"Question","@id":"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/#faq-question-1770222835773","position":6,"url":"https:\/\/www.han-sphere.com\/blog\/news\/hdi-microvias-blind-buried-via-design\/#faq-question-1770222835773","name":"Q: 6. Do microvias improve signal integrity?","answerCount":1,"acceptedAnswer":{"@type":"Answer","text":"A: Yes. Shorter via length reduces parasitic inductance and reflections.","inLanguage":"es"},"inLanguage":"es"}]}},"_links":{"self":[{"href":"https:\/\/www.han-sphere.com\/es\/wp-json\/wp\/v2\/posts\/309","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.han-sphere.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.han-sphere.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.han-sphere.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.han-sphere.com\/es\/wp-json\/wp\/v2\/comments?post=309"}],"version-history":[{"count":2,"href":"https:\/\/www.han-sphere.com\/es\/wp-json\/wp\/v2\/posts\/309\/revisions"}],"predecessor-version":[{"id":376,"href":"https:\/\/www.han-sphere.com\/es\/wp-json\/wp\/v2\/posts\/309\/revisions\/376"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.han-sphere.com\/es\/wp-json\/wp\/v2\/media\/311"}],"wp:attachment":[{"href":"https:\/\/www.han-sphere.com\/es\/wp-json\/wp\/v2\/media?parent=309"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.han-sphere.com\/es\/wp-json\/wp\/v2\/categories?post=309"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.han-sphere.com\/es\/wp-json\/wp\/v2\/tags?post=309"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}