{"id":583,"date":"2026-04-12T08:27:00","date_gmt":"2026-04-12T00:27:00","guid":{"rendered":"https:\/\/www.han-sphere.com\/?p=583"},"modified":"2026-04-07T23:35:12","modified_gmt":"2026-04-07T15:35:12","slug":"ipc-class-2-vs-class-3-pcb-standards","status":"publish","type":"post","link":"https:\/\/www.han-sphere.com\/fr\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/","title":{"rendered":"Classe 2 IPC ou classe 3 : quelle norme votre fournisseur de circuits imprim\u00e9s et votre usine respectent-ils ?"},"content":{"rendered":"<p class=\"wp-block-paragraph\">In the PCB industry, &#8220;quality&#8221; isn&#8217;t a subjective feeling\u2014it is a measurable set of standards defined by IPC (Association Connecting Electronics Industries). When you request a quote from a <strong>Fournisseur de circuits imprim\u00e9s<\/strong>, l'une des premi\u00e8res questions auxquelles vous devriez pouvoir r\u00e9pondre est la suivante : <strong>Avez-vous besoin d'un produit de classe 2 ou de classe 3 selon la norme IPC ?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Choisir la mauvaise classe peut entra\u00eener soit des co\u00fbts inutiles, soit, pire encore, des d\u00e9faillances pr\u00e9matur\u00e9es sur le terrain. Voici comment un professionnel <strong>Usine de circuits imprim\u00e9s<\/strong> fait la distinction entre ces deux niveaux de fabrication.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"469\" src=\"http:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/03\/FR4-PCB-12.jpg\" alt=\"Circuit imprim\u00e9 FR4\" class=\"wp-image-517\" srcset=\"https:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/03\/FR4-PCB-12.jpg 600w, https:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/03\/FR4-PCB-12-300x235.jpg 300w, https:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/03\/FR4-PCB-12-15x12.jpg 15w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\">1. La diff\u00e9rence fondamentale<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Classe 2 de l'IPC (produits \u00e9lectroniques \u00e0 usage sp\u00e9cifique) :<\/strong> Il s'agit de la norme applicable \u00e0 la plupart des appareils \u00e9lectroniques grand public, des ordinateurs portables et des appareils \u00e9lectrom\u00e9nagers. Elle autorise certaines imperfections qui n'affectent ni le fonctionnement global ni la dur\u00e9e de vie de la carte.<\/li>\n\n\n\n<li><strong>Classe 3 de l'IPC (produits \u00e9lectroniques \u00e0 haute fiabilit\u00e9) :<\/strong> C'est une exigence incontournable pour les applications m\u00e9dicales, a\u00e9rospatiales et militaires. Il existe <strong>tol\u00e9rance z\u00e9ro<\/strong> en cas de panne des \u00e9quipements, et les conditions environnementales peuvent \u00eatre particuli\u00e8rement difficiles.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">2. Variations critiques de fabrication<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A <strong>Usine de circuits imprim\u00e9s<\/strong> traite ces deux classes avec des niveaux de rigueur diff\u00e9rents :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Anneaux annulaires :<\/strong> La classe 3 exige une \u00e9paisseur minimale de 0,050 mm (2 mils) de cuivre autour du trou perc\u00e9, tandis que la classe 2 autorise un certain \u00ab d\u00e9bord \u00bb (lorsque le trou n\u2019est pas parfaitement centr\u00e9 sur la pastille).<\/li>\n\n\n\n<li><strong>Cuivrage :<\/strong> Pour la classe 3, un syst\u00e8me fiable <strong>Fournisseur de circuits imprim\u00e9s<\/strong> will ensure the hole-wall plating is at least 25\u00b5m thick, compared to 20\u00b5m for Class 2. This is verified via the <strong>Protocoles d'essai sp\u00e9cifiques<\/strong> que nous utilisons pour \u00e9viter la fissuration du f\u00fbt lors des cycles thermiques.<\/li>\n\n\n\n<li><strong>Positionnement des composants :<\/strong> La classe 3 impose des exigences bien plus strictes en mati\u00e8re d'alignement des composants et de mouillage des cordons de soudure.<\/li>\n<\/ul>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"427\" src=\"http:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/03\/Rigid-Flex-PCB-2.jpg\" alt=\"Circuit imprim\u00e9 rigide-flexible\" class=\"wp-image-412\" srcset=\"https:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/03\/Rigid-Flex-PCB-2.jpg 600w, https:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/03\/Rigid-Flex-PCB-2-300x214.jpg 300w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\">Comment d\u00e9terminer la classe IPC qui correspond \u00e0 votre projet<\/h2>\n\n\n\n<div class=\"schema-how-to wp-block-yoast-how-to-block\"><p class=\"schema-how-to-description\">Suivez cette d\u00e9marche logique pour choisir la norme de fabrication adapt\u00e9e \u00e0 votre prochaine commande chez notre <strong>Usine de circuits imprim\u00e9s<\/strong>:<\/p> <ol class=\"schema-how-to-steps\"><li class=\"schema-how-to-step\" id=\"how-to-step-1775575867678\"><strong class=\"schema-how-to-step-name\"><strong>\u00c9valuer le risque d'\u00e9chec<\/strong><\/strong> <p class=\"schema-how-to-step-text\">Si une d\u00e9faillance entra\u00eene un risque pour la s\u00e9curit\u00e9 ou une perte financi\u00e8re consid\u00e9rable (par exemple, dans le cas d'un satellite ou d'un moniteur cardiaque), <strong>La classe 3 est obligatoire<\/strong>.<\/p> <\/li><li class=\"schema-how-to-step\" id=\"how-to-step-1775575879308\"><strong class=\"schema-how-to-step-name\"><strong>\u00c9valuer l'environnement d'exploitation<\/strong><\/strong> <p class=\"schema-how-to-step-text\">La carte sera-t-elle soumise \u00e0 des vibrations ou \u00e0 des temp\u00e9ratures extr\u00eames ? Si tel est le cas, l'\u00e9paisseur suppl\u00e9mentaire de cuivre de la classe 3 est n\u00e9cessaire pour <strong>Pr\u00e9venir les pannes de carte \u00e9lectronique<\/strong><\/p> <\/li><li class=\"schema-how-to-step\" id=\"how-to-step-1775575911537\"><strong class=\"schema-how-to-step-name\"><strong>V\u00e9rifiez votre budget<\/strong><\/strong> <p class=\"schema-how-to-step-text\">La classe 3 est plus ch\u00e8re car le <strong>Usine de circuits imprim\u00e9s<\/strong> doit ralentir la production pour permettre des contr\u00f4les suppl\u00e9mentaires et respecter des tol\u00e9rances plus strictes.<\/p> <\/li><li class=\"schema-how-to-step\" id=\"how-to-step-1775575918765\"><strong class=\"schema-how-to-step-name\"><strong>Audit the Supplier\u2019s Capability<\/strong><\/strong> <p class=\"schema-how-to-step-text\">Toutes les usines ne sont pas en mesure de respecter les exigences de la classe 3. Avant de commencer, vous devez <strong><a href=\"https:\/\/www.han-sphere.com\/blog\/news\/audit-pcb-supplier-pcb-factory-checkpoints\/\">Audit de l'usine du fournisseur de circuits imprim\u00e9s<\/a><\/strong> afin de s'assurer qu'ils disposent des \u00e9quipements de radiographie et de d\u00e9coupage en tranches n\u00e9cessaires \u00e0 la v\u00e9rification de classe 3.<\/p> <\/li><li class=\"schema-how-to-step\" id=\"how-to-step-1775575944208\"><strong class=\"schema-how-to-step-name\"><strong>Consultez l'\u00e9quipe CAM<\/strong><\/strong> <p class=\"schema-how-to-step-text\">Au cours de la <strong><a href=\"https:\/\/www.han-sphere.com\/blog\/news\/pcb-supplier-factory-order-workflow\/\">Phase du processus de traitement des commandes<\/a><\/strong>, demandez aux ing\u00e9nieurs si les rapports \u00ab trace-to-pad \u00bb de votre conception permettent r\u00e9ellement de respecter les exigences relatives aux anneaux annulaires de classe 3.<\/p> <\/li><\/ol><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Le r\u00f4le de la conformit\u00e9 : RoHS et UL<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Au-del\u00e0 des classes IPC, un syst\u00e8me global <strong>Fournisseur de circuits imprim\u00e9s<\/strong> doit \u00e9galement veiller au respect des normes environnementales et de s\u00e9curit\u00e9. Notre <strong>Usine de circuits imprim\u00e9s<\/strong> garantit que tous les mat\u00e9riaux sont conformes \u00e0 la directive RoHS (sans plomb) et certifi\u00e9s UL, ce qui est essentiel pour p\u00e9n\u00e9trer les march\u00e9s nord-am\u00e9ricain et europ\u00e9en. Ce contr\u00f4le \u00ab en source \u00bb des mat\u00e9riaux constitue un atout majeur <strong><a href=\"https:\/\/www.han-sphere.com\/blog\/news\/direct-pcb-factory-vs-supplier-advantages\/\">Les avantages de travailler directement avec un fabricant de circuits imprim\u00e9s<\/a><\/strong> par rapport au recours \u00e0 un courtier qui pourrait s'approvisionner aupr\u00e8s de magasins non v\u00e9rifi\u00e9s.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">FAQ : Normes et conformit\u00e9 des circuits imprim\u00e9s<\/h2>\n\n\n\n<div class=\"schema-faq wp-block-yoast-faq-block\"><div class=\"schema-faq-section\" id=\"faq-question-1775576016578\"><strong class=\"schema-faq-question\"><strong>Q : Puis-je associer des \u00e9l\u00e9ments de classe 2 et de classe 3 sur le m\u00eame panneau ?<\/strong><\/strong> <p class=\"schema-faq-answer\"><strong>A:<\/strong> Non. A <strong>Usine de circuits imprim\u00e9s<\/strong> Il faut adapter l'ensemble de la cha\u00eene de production aux exigences les plus strictes de la commande. Vous devez choisir une seule norme pour l'ensemble du cycle de fabrication.<\/p> <\/div> <div class=\"schema-faq-section\" id=\"faq-question-1775576024629\"><strong class=\"schema-faq-question\"><strong>Q : La fabrication des produits de classe 3 selon la norme IPC prend-elle plus de temps ?<\/strong><\/strong> <p class=\"schema-faq-answer\"><strong>A:<\/strong> Oui. En raison du nombre accru de contr\u00f4les qualit\u00e9 et de tests \u00e9lectriques plus rigoureux, les commandes de classe 3 entra\u00eenent g\u00e9n\u00e9ralement un allongement de 2 \u00e0 3 jours du d\u00e9lai de livraison standard.<\/p> <\/div> <div class=\"schema-faq-section\" id=\"faq-question-1775576034025\"><strong class=\"schema-faq-question\"><strong>Q : La classe 1 de l'IPC est-elle toujours utilis\u00e9e ?<\/strong><\/strong> <p class=\"schema-faq-answer\"><strong>A:<\/strong> La classe 1 de l'IPC (produits \u00e9lectroniques g\u00e9n\u00e9raux) est aujourd'hui rarement utilis\u00e9e. La plupart des professionnels <strong>Fournisseurs de circuits imprim\u00e9s<\/strong> consid\u00e9rer la classe 2 comme leur niveau de qualit\u00e9 minimum de r\u00e9f\u00e9rence.<\/p> <\/div> <\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Assurez la p\u00e9rennit\u00e9 de vos conceptions avec Han-Sphere<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">At <a target=\"_blank\" rel=\"noreferrer noopener\" href=\"https:\/\/www.han-sphere.com\/\">Han-Sphere<\/a>, nous vous aidons \u00e0 vous y retrouver dans les subtilit\u00e9s des normes internationales. Que vous ayez besoin de cartes de classe 2 \u00e0 prix comp\u00e9titif pour le lancement d\u2019un produit grand public ou de cartes de classe 3 \u00e0 haute fiabilit\u00e9 pour du mat\u00e9riel industriel, notre <strong>Usine de circuits imprim\u00e9s<\/strong> est pr\u00eat \u00e0 livrer.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Pr\u00eat \u00e0 am\u00e9liorer les caract\u00e9ristiques de ta planche ?<\/strong> <a target=\"_blank\" rel=\"noreferrer noopener\" href=\"https:\/\/www.han-sphere.com\/contact\/\">Discutez avec nos experts en conformit\u00e9<\/a> d\u00e8s aujourd'hui pour vous assurer que votre prochaine r\u00e9alisation r\u00e9ponde \u00e0 toutes les exigences du secteur.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Ne laissez pas une mauvaise compr\u00e9hension des normes IPC compromettre la fiabilit\u00e9 de votre produit. Cette analyse approfondie explique les diff\u00e9rences essentielles entre les classes 2 et 3 de l\u2019IPC. D\u00e9couvrez comment un fournisseur professionnel de circuits imprim\u00e9s g\u00e8re les tol\u00e9rances et les contr\u00f4les au sein de son usine afin de r\u00e9pondre aux exigences rigoureuses des secteurs de l\u2019a\u00e9rospatiale, du m\u00e9dical et de l\u2019\u00e9lectronique industrielle.<\/p>","protected":false},"author":1,"featured_media":514,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":"","footnotes":""},"categories":[4],"tags":[46],"class_list":["post-583","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news","tag-pcb-supplier"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>IPC Class 2 vs. Class 3: Which Standard Does Your PCB Supplier and Factory Follow?<\/title>\n<meta name=\"description\" content=\"Understand the difference between IPC Class 2 and Class 3 standards. Learn how a high-quality PCB supplier ensures compliance within the PCB factory for mission-critical apps.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.han-sphere.com\/fr\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"IPC Class 2 vs. Class 3: Which Standard Does Your PCB Supplier and Factory Follow?\" \/>\n<meta property=\"og:description\" content=\"Understand the difference between IPC Class 2 and Class 3 standards. Learn how a high-quality PCB supplier ensures compliance within the PCB factory for mission-critical apps.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.han-sphere.com\/fr\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/\" \/>\n<meta property=\"og:site_name\" content=\"hansphere\" \/>\n<meta property=\"article:published_time\" content=\"2026-04-12T00:27:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/03\/FR4-PCB-11.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"600\" \/>\n\t<meta property=\"og:image:height\" content=\"521\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"hansphere01\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"hansphere01\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":[\"WebPage\",\"FAQPage\"],\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/\",\"url\":\"https:\/\/www.han-sphere.com\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/\",\"name\":\"IPC Class 2 vs. Class 3: Which Standard Does Your PCB Supplier and Factory Follow?\",\"isPartOf\":{\"@id\":\"https:\/\/www.han-sphere.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/03\/FR4-PCB-11.jpg\",\"datePublished\":\"2026-04-12T00:27:00+00:00\",\"author\":{\"@id\":\"https:\/\/www.han-sphere.com\/#\/schema\/person\/a8f2356806898d33a9f431801140e422\"},\"description\":\"Understand the difference between IPC Class 2 and Class 3 standards. Learn how a high-quality PCB supplier ensures compliance within the PCB factory for mission-critical apps.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/#breadcrumb\"},\"mainEntity\":[{\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/#faq-question-1775576016578\"},{\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/#faq-question-1775576024629\"},{\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/#faq-question-1775576034025\"}],\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.han-sphere.com\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/#primaryimage\",\"url\":\"https:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/03\/FR4-PCB-11.jpg\",\"contentUrl\":\"https:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/03\/FR4-PCB-11.jpg\",\"width\":600,\"height\":521,\"caption\":\"FR4 PCB\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.han-sphere.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"IPC Class 2 vs. Class 3: Which Standard Does Your PCB Supplier and Factory Follow?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.han-sphere.com\/#website\",\"url\":\"https:\/\/www.han-sphere.com\/\",\"name\":\"hansphere\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.han-sphere.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.han-sphere.com\/#\/schema\/person\/a8f2356806898d33a9f431801140e422\",\"name\":\"hansphere01\",\"sameAs\":[\"http:\/\/www.han-sphere.com\/\"],\"url\":\"https:\/\/www.han-sphere.com\/fr\/author\/hansphere01\/\"},{\"@type\":\"Question\",\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/#faq-question-1775576016578\",\"position\":1,\"url\":\"https:\/\/www.han-sphere.com\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/#faq-question-1775576016578\",\"name\":\"Q: Can I mix Class 2 and Class 3 on the same board?\",\"answerCount\":1,\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"<strong>A:<\/strong> No. A <strong>PCB factory<\/strong> must set the entire production line to the strictest requirement of the order. You must choose one standard for the entire manufacturing run.\",\"inLanguage\":\"fr-FR\"},\"inLanguage\":\"fr-FR\"},{\"@type\":\"Question\",\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/#faq-question-1775576024629\",\"position\":2,\"url\":\"https:\/\/www.han-sphere.com\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/#faq-question-1775576024629\",\"name\":\"Q: Does IPC Class 3 take longer to manufacture?\",\"answerCount\":1,\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"<strong>A:<\/strong> Yes. Due to the increased number of quality gates and more rigorous electrical testing, Class 3 orders typically add 2-3 days to the standard lead time.\",\"inLanguage\":\"fr-FR\"},\"inLanguage\":\"fr-FR\"},{\"@type\":\"Question\",\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/#faq-question-1775576034025\",\"position\":3,\"url\":\"https:\/\/www.han-sphere.com\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/#faq-question-1775576034025\",\"name\":\"Q: Is IPC Class 1 still used?\",\"answerCount\":1,\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"<strong>A:<\/strong> IPC Class 1 (General Electronic Products) is rarely used today. Most professional <strong>PCB suppliers<\/strong> treat Class 2 as their minimum baseline for quality.\",\"inLanguage\":\"fr-FR\"},\"inLanguage\":\"fr-FR\"},{\"@type\":\"HowTo\",\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/#howto-1\",\"name\":\"IPC Class 2 vs. Class 3: Which Standard Does Your PCB Supplier and Factory Follow?\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/\"},\"description\":\"Follow this logical process to choose the right manufacturing standard for your next order at our &lt;strong>PCB factory&lt;\/strong>:\",\"step\":[{\"@type\":\"HowToStep\",\"url\":\"https:\/\/www.han-sphere.com\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/#how-to-step-1775575867678\",\"name\":\"Assess the Risk of Failure\",\"itemListElement\":[{\"@type\":\"HowToDirection\",\"text\":\"If a failure results in a safety hazard or massive financial loss (e.g., a satellite or a heart monitor), <strong>Class 3 is mandatory<\/strong>.\"}]},{\"@type\":\"HowToStep\",\"url\":\"https:\/\/www.han-sphere.com\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/#how-to-step-1775575879308\",\"name\":\"Evaluate the Operating Environment\",\"itemListElement\":[{\"@type\":\"HowToDirection\",\"text\":\"Will the board face extreme vibrations or temperatures? If so, the extra copper thickness of Class 3 is necessary to <strong>Prevent Board Failures<\/strong>\"}]},{\"@type\":\"HowToStep\",\"url\":\"https:\/\/www.han-sphere.com\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/#how-to-step-1775575911537\",\"name\":\"Review Your Budget\",\"itemListElement\":[{\"@type\":\"HowToDirection\",\"text\":\"Class 3 is more expensive because the <strong>PCB factory<\/strong> must slow down production for extra inspections and tighter tolerances.\"}]},{\"@type\":\"HowToStep\",\"url\":\"https:\/\/www.han-sphere.com\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/#how-to-step-1775575918765\",\"name\":\"Audit the Supplier\u2019s Capability\",\"itemListElement\":[{\"@type\":\"HowToDirection\",\"text\":\"Not every factory can meet Class 3. Before starting, you should <strong><a href=\\\"https:\/\/www.han-sphere.com\/blog\/news\/audit-pcb-supplier-pcb-factory-checkpoints\/\\\">Audit the PCB Supplier's Factory<\/a><\/strong> to ensure they have the X-ray and cross-sectioning equipment required for Class 3 verification.\"}]},{\"@type\":\"HowToStep\",\"url\":\"https:\/\/www.han-sphere.com\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/#how-to-step-1775575944208\",\"name\":\"Consult the CAM Team\",\"itemListElement\":[{\"@type\":\"HowToDirection\",\"text\":\"During the <strong><a href=\\\"https:\/\/www.han-sphere.com\/blog\/news\/pcb-supplier-factory-order-workflow\/\\\">Order Workflow Phase<\/a><\/strong>, ask the engineers if your design's trace-to-pad ratios can realistically meet Class 3 annular ring requirements.\"}]}],\"inLanguage\":\"fr-FR\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Classe 2 IPC ou classe 3 : quelle norme votre fournisseur de circuits imprim\u00e9s et votre usine respectent-ils ?","description":"Comprenez la diff\u00e9rence entre les normes IPC de classe 2 et de classe 3. D\u00e9couvrez comment un fournisseur de circuits imprim\u00e9s de haute qualit\u00e9 garantit la conformit\u00e9 au sein de son usine pour les applications critiques.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.han-sphere.com\/fr\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/","og_locale":"fr_FR","og_type":"article","og_title":"IPC Class 2 vs. Class 3: Which Standard Does Your PCB Supplier and Factory Follow?","og_description":"Understand the difference between IPC Class 2 and Class 3 standards. Learn how a high-quality PCB supplier ensures compliance within the PCB factory for mission-critical apps.","og_url":"https:\/\/www.han-sphere.com\/fr\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/","og_site_name":"hansphere","article_published_time":"2026-04-12T00:27:00+00:00","og_image":[{"width":600,"height":521,"url":"https:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/03\/FR4-PCB-11.jpg","type":"image\/jpeg"}],"author":"hansphere01","twitter_card":"summary_large_image","twitter_misc":{"\u00c9crit par":"hansphere01","Dur\u00e9e de lecture estim\u00e9e":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":["WebPage","FAQPage"],"@id":"https:\/\/www.han-sphere.com\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/","url":"https:\/\/www.han-sphere.com\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/","name":"Classe 2 IPC ou classe 3 : quelle norme votre fournisseur de circuits imprim\u00e9s et votre usine respectent-ils ?","isPartOf":{"@id":"https:\/\/www.han-sphere.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.han-sphere.com\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/#primaryimage"},"image":{"@id":"https:\/\/www.han-sphere.com\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/#primaryimage"},"thumbnailUrl":"https:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/03\/FR4-PCB-11.jpg","datePublished":"2026-04-12T00:27:00+00:00","author":{"@id":"https:\/\/www.han-sphere.com\/#\/schema\/person\/a8f2356806898d33a9f431801140e422"},"description":"Comprenez la diff\u00e9rence entre les normes IPC de classe 2 et de classe 3. D\u00e9couvrez comment un fournisseur de circuits imprim\u00e9s de haute qualit\u00e9 garantit la conformit\u00e9 au sein de son usine pour les applications critiques.","breadcrumb":{"@id":"https:\/\/www.han-sphere.com\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/#breadcrumb"},"mainEntity":[{"@id":"https:\/\/www.han-sphere.com\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/#faq-question-1775576016578"},{"@id":"https:\/\/www.han-sphere.com\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/#faq-question-1775576024629"},{"@id":"https:\/\/www.han-sphere.com\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/#faq-question-1775576034025"}],"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.han-sphere.com\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.han-sphere.com\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/#primaryimage","url":"https:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/03\/FR4-PCB-11.jpg","contentUrl":"https:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/03\/FR4-PCB-11.jpg","width":600,"height":521,"caption":"FR4 PCB"},{"@type":"BreadcrumbList","@id":"https:\/\/www.han-sphere.com\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.han-sphere.com\/"},{"@type":"ListItem","position":2,"name":"IPC Class 2 vs. Class 3: Which Standard Does Your PCB Supplier and Factory Follow?"}]},{"@type":"WebSite","@id":"https:\/\/www.han-sphere.com\/#website","url":"https:\/\/www.han-sphere.com\/","name":"hansphere","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.han-sphere.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Person","@id":"https:\/\/www.han-sphere.com\/#\/schema\/person\/a8f2356806898d33a9f431801140e422","name":"hansphere01","sameAs":["http:\/\/www.han-sphere.com\/"],"url":"https:\/\/www.han-sphere.com\/fr\/author\/hansphere01\/"},{"@type":"Question","@id":"https:\/\/www.han-sphere.com\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/#faq-question-1775576016578","position":1,"url":"https:\/\/www.han-sphere.com\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/#faq-question-1775576016578","name":"Q : Puis-je associer des \u00e9l\u00e9ments de classe 2 et de classe 3 sur le m\u00eame panneau ?","answerCount":1,"acceptedAnswer":{"@type":"Answer","text":"<strong>A:<\/strong> No. A <strong>PCB factory<\/strong> must set the entire production line to the strictest requirement of the order. You must choose one standard for the entire manufacturing run.","inLanguage":"fr-FR"},"inLanguage":"fr-FR"},{"@type":"Question","@id":"https:\/\/www.han-sphere.com\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/#faq-question-1775576024629","position":2,"url":"https:\/\/www.han-sphere.com\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/#faq-question-1775576024629","name":"Q : La fabrication des produits de classe 3 selon la norme IPC prend-elle plus de temps ?","answerCount":1,"acceptedAnswer":{"@type":"Answer","text":"<strong>A:<\/strong> Yes. Due to the increased number of quality gates and more rigorous electrical testing, Class 3 orders typically add 2-3 days to the standard lead time.","inLanguage":"fr-FR"},"inLanguage":"fr-FR"},{"@type":"Question","@id":"https:\/\/www.han-sphere.com\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/#faq-question-1775576034025","position":3,"url":"https:\/\/www.han-sphere.com\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/#faq-question-1775576034025","name":"Q : La classe 1 de l'IPC est-elle toujours utilis\u00e9e ?","answerCount":1,"acceptedAnswer":{"@type":"Answer","text":"<strong>A:<\/strong> IPC Class 1 (General Electronic Products) is rarely used today. Most professional <strong>PCB suppliers<\/strong> treat Class 2 as their minimum baseline for quality.","inLanguage":"fr-FR"},"inLanguage":"fr-FR"},{"@type":"HowTo","@id":"https:\/\/www.han-sphere.com\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/#howto-1","name":"Classe 2 IPC ou classe 3 : quelle norme votre fournisseur de circuits imprim\u00e9s et votre usine respectent-ils ?","mainEntityOfPage":{"@id":"https:\/\/www.han-sphere.com\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/"},"description":"Suivez cette d&eacute;marche logique pour choisir la norme de fabrication adapt&eacute;e &agrave; votre prochaine commande chez notre &lt;strong&gt;Usine de circuits imprim&eacute;s&lt;\/strong&gt;:","step":[{"@type":"HowToStep","url":"https:\/\/www.han-sphere.com\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/#how-to-step-1775575867678","name":"Assess the Risk of Failure","itemListElement":[{"@type":"HowToDirection","text":"If a failure results in a safety hazard or massive financial loss (e.g., a satellite or a heart monitor), <strong>Class 3 is mandatory<\/strong>."}]},{"@type":"HowToStep","url":"https:\/\/www.han-sphere.com\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/#how-to-step-1775575879308","name":"Evaluate the Operating Environment","itemListElement":[{"@type":"HowToDirection","text":"Will the board face extreme vibrations or temperatures? If so, the extra copper thickness of Class 3 is necessary to <strong>Prevent Board Failures<\/strong>"}]},{"@type":"HowToStep","url":"https:\/\/www.han-sphere.com\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/#how-to-step-1775575911537","name":"Review Your Budget","itemListElement":[{"@type":"HowToDirection","text":"Class 3 is more expensive because the <strong>PCB factory<\/strong> must slow down production for extra inspections and tighter tolerances."}]},{"@type":"HowToStep","url":"https:\/\/www.han-sphere.com\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/#how-to-step-1775575918765","name":"Audit the Supplier\u2019s Capability","itemListElement":[{"@type":"HowToDirection","text":"Not every factory can meet Class 3. Before starting, you should <strong><a href=\"https:\/\/www.han-sphere.com\/blog\/news\/audit-pcb-supplier-pcb-factory-checkpoints\/\">Audit the PCB Supplier's Factory<\/a><\/strong> to ensure they have the X-ray and cross-sectioning equipment required for Class 3 verification."}]},{"@type":"HowToStep","url":"https:\/\/www.han-sphere.com\/blog\/news\/ipc-class-2-vs-class-3-pcb-standards\/#how-to-step-1775575944208","name":"Consult the CAM Team","itemListElement":[{"@type":"HowToDirection","text":"During the <strong><a href=\"https:\/\/www.han-sphere.com\/blog\/news\/pcb-supplier-factory-order-workflow\/\">Order Workflow Phase<\/a><\/strong>, ask the engineers if your design's trace-to-pad ratios can realistically meet Class 3 annular ring requirements."}]}],"inLanguage":"fr-FR"}]}},"_links":{"self":[{"href":"https:\/\/www.han-sphere.com\/fr\/wp-json\/wp\/v2\/posts\/583","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.han-sphere.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.han-sphere.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.han-sphere.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.han-sphere.com\/fr\/wp-json\/wp\/v2\/comments?post=583"}],"version-history":[{"count":1,"href":"https:\/\/www.han-sphere.com\/fr\/wp-json\/wp\/v2\/posts\/583\/revisions"}],"predecessor-version":[{"id":584,"href":"https:\/\/www.han-sphere.com\/fr\/wp-json\/wp\/v2\/posts\/583\/revisions\/584"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.han-sphere.com\/fr\/wp-json\/wp\/v2\/media\/514"}],"wp:attachment":[{"href":"https:\/\/www.han-sphere.com\/fr\/wp-json\/wp\/v2\/media?parent=583"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.han-sphere.com\/fr\/wp-json\/wp\/v2\/categories?post=583"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.han-sphere.com\/fr\/wp-json\/wp\/v2\/tags?post=583"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}