{"id":553,"date":"2026-03-29T08:33:00","date_gmt":"2026-03-29T00:33:00","guid":{"rendered":"https:\/\/www.han-sphere.com\/?p=553"},"modified":"2026-03-26T00:00:46","modified_gmt":"2026-03-25T16:00:46","slug":"fr4-dielectric-constant-er-vs-frequency","status":"publish","type":"post","link":"https:\/\/www.han-sphere.com\/sv\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/","title":{"rendered":"F\u00f6rklaring av FR4:s dielektricitetskonstant (Er) i f\u00f6rh\u00e5llande till frekvensen"},"content":{"rendered":"<p class=\"wp-block-paragraph\">If you\u2019ve ever tried to match impedance on an FR4 stackup and found the numbers drifting, you\u2019ve already run into this problem.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">FR4 doesn\u2019t have a single dielectric constant. The value changes with frequency, and that change is enough to affect impedance, especially once you move beyond low-speed digital designs.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">I de flesta datablad anges fortfarande n\u00e5got i stil med <strong>Er = 4.2\u20134.6<\/strong>, men det v\u00e4rdet \u00e4r endast meningsfullt under specifika testf\u00f6rh\u00e5llanden. I verkliga konstruktioner \u00e4r det avg\u00f6rande hur Er beter sig \u00f6ver hela det faktiska frekvensomr\u00e5det.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">F\u00f6r en mer omfattande \u00f6versikt \u00f6ver materialet, se <a href=\"https:\/\/www.han-sphere.com\/blog\/news\/fr4-pcb-material-guide-properties-applications\/\"><strong>Guide till FR4-kretskortmaterial: Egenskaper, f\u00f6rdelar och anv\u00e4ndningsomr\u00e5den<\/strong>.<\/a><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"517\" src=\"http:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/03\/FR4-PCB-17.jpg\" alt=\"FR4-kretskort\" class=\"wp-image-524\" srcset=\"https:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/03\/FR4-PCB-17.jpg 600w, https:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/03\/FR4-PCB-17-300x259.jpg 300w, https:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/03\/FR4-PCB-17-14x12.jpg 14w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\">Vad \u00e4r den dielektriska konstanten (Er)?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Dielektricitetskonstanten (Er) beskriver hur ett material lagrar elektrisk energi i ett elektriskt f\u00e4lt.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Vid kretskortsdesign p\u00e5verkar Er direkt:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>signalens utbredningshastighet<\/li>\n\n\n\n<li>karakteristisk impedans<\/li>\n\n\n\n<li>f\u00f6rdr\u00f6jning i sp\u00e5rningen<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Higher Er \u2192 slower signal propagation \u2192 shorter wavelength in the material.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">That\u2019s why Er shows up in every impedance calculator.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Varf\u00f6r Er varierar med frekvensen<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">FR4 is not a uniform material. It\u2019s a mix of:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>glasfiber (l\u00e5g f\u00f6rlust, l\u00e4gre Er)<\/li>\n\n\n\n<li>epoxiharts (h\u00f6gre f\u00f6rlust, h\u00f6gre Er)<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">P\u00e5 grund av denna struktur beror dess elektriska beteende p\u00e5 frekvensen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">N\u00e4r frekvensen \u00f6kar:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>f\u00f6r\u00e4ndringar i polariseringsmekanismerna inuti hartset<\/li>\n\n\n\n<li>den effektiva dielektricitetskonstanten tenderar att <strong>minska n\u00e5got<\/strong><\/li>\n\n\n\n<li>den dielektriska f\u00f6rlusten blir mer m\u00e4rkbar<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">I praktiken inneb\u00e4r det f\u00f6ljande:<br><strong>Er vid 100 MHz \u00e4r inte detsamma som Er vid flera GHz.<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Typiska Er-v\u00e4rden j\u00e4mf\u00f6rt med frekvens<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">You won\u2019t get one universal curve, but the general trend looks like this:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Frekvensintervall Maskeringsf\u00e4rg<\/th><th>Typisk FR4 Er<\/th><\/tr><\/thead><tbody><tr><td>1 MHz<\/td><td>~4.5\u20134.8<\/td><\/tr><tr><td>100 MHz<\/td><td>~4.3\u20134.6<\/td><\/tr><tr><td>1 GHz<\/td><td>~4.2\u20134.5<\/td><\/tr><tr><td>5\u201310 GHz<\/td><td>~4.0\u20134.3<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">De faktiska v\u00e4rdena varierar beroende p\u00e5 leverant\u00f6r och hartssystem.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Denna variation \u00e4r en av anledningarna till att man i h\u00f6gfrekventa konstruktioner ofta v\u00e4ljer bort FR4.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Mer om det h\u00e4r: <strong><a href=\"https:\/\/www.han-sphere.com\/blog\/news\/fr4-vs-rogers-pcb-high-frequency-design\/\">FR4 j\u00e4mf\u00f6rt med Rogers-kretskort f\u00f6r h\u00f6gfrekvenskonstruktion<\/a><\/strong>.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"499\" src=\"http:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/03\/FR4-PCB-15.jpg\" alt=\"FR4-kretskort\" class=\"wp-image-520\" srcset=\"https:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/03\/FR4-PCB-15.jpg 600w, https:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/03\/FR4-PCB-15-300x250.jpg 300w, https:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/03\/FR4-PCB-15-14x12.jpg 14w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\">Inverkan p\u00e5 impedansregleringen<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">If you assume a fixed Er in your calculations, your impedance won\u2019t be exact.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Effekterna visar sig i form av:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>avvikelse mellan ber\u00e4knad och faktisk impedans<\/li>\n\n\n\n<li>signalreflektioner<\/li>\n\n\n\n<li>f\u00f6rvr\u00e4ngda \u00f6gondiagram (i h\u00f6ghastighetsf\u00f6rbindelser)<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Redan en liten f\u00f6rskjutning i Er-v\u00e4rdet kan f\u00f6r\u00e4ndra impedansen med n\u00e5gra ohm, vilket \u00e4r tillr\u00e4ckligt f\u00f6r att det ska ha betydelse i konstruktioner med kontrollerad impedans.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u00d6verv\u00e4ganden kring stackup-konstruktion behandlas i <strong><a href=\"https:\/\/www.han-sphere.com\/blog\/news\/fr4-pcb-stackup-design-guide\/\">Guide till utformning av FR4-kretskortets skiktuppbyggnad<\/a><\/strong>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Variationer inom samma kretskort<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">En annan praktisk fr\u00e5ga: Er \u00e4r inte helt enhetligt \u00f6ver hela linjen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Eftersom sp\u00e5r kan str\u00e4cka sig \u00f6ver:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>omr\u00e5den med h\u00f6gre halt av harts<\/li>\n\n\n\n<li>omr\u00e5den med st\u00f6rre glasandel<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Det kan f\u00f6rekomma lokala variationer.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Detta kallas ibland f\u00f6r <strong>\u201cfiber weave effect\u201d<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Det kan leda till:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>skevhet mellan differentialpar<\/li>\n\n\n\n<li>liten impedansvariation l\u00e4ngs ledningen<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Not always critical\u2014but it shows up in high-speed designs.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Hur man arbetar med FR4 Er i verkliga konstruktioner<\/h2>\n\n\n\n<div class=\"schema-how-to wp-block-yoast-how-to-block\"><p class=\"schema-how-to-description\">You don\u2019t need perfect data\u2014you need realistic assumptions.<\/p> <ol class=\"schema-how-to-steps\"><li class=\"schema-how-to-step\" id=\"how-to-step-1774453565242\"><strong class=\"schema-how-to-step-name\">1. Anv\u00e4nd tillverkarens stapeldata<\/strong> <p class=\"schema-how-to-step-text\">Don\u2019t rely on generic Er values.<br\/>Anv\u00e4ndning:<br\/>datablad f\u00f6r laminat<br\/>impedanstabeller fr\u00e5n din kretskortleverant\u00f6r<br\/>They\u2019re closer to actual fabrication conditions.<\/p> <\/li><li class=\"schema-how-to-step\" id=\"how-to-step-1774453593981\"><strong class=\"schema-how-to-step-name\">2. Utforma kretsen utifr\u00e5n m\u00e5limpedansen, inte den nominella impedansen<\/strong> <p class=\"schema-how-to-step-text\">I st\u00e4llet f\u00f6r att direkt fokusera p\u00e5 Er:<br\/>define target impedance (e.g., 50\u03a9, 100\u03a9 diff)<br\/>justera linjernas bredd och avst\u00e5nd d\u00e4refter<br\/>L\u00e5t tillverkaren hj\u00e4lpa till att finjustera materialuppbyggnaden.<\/p> <\/li><li class=\"schema-how-to-step\" id=\"how-to-step-1774453621498\"><strong class=\"schema-how-to-step-name\">3. Var f\u00f6rsiktig vid h\u00f6gre frekvenser<\/strong> <p class=\"schema-how-to-step-text\">N\u00e4r frekvensen \u00f6kar:<br\/>os\u00e4kerheten \u00f6kar<br\/>f\u00f6rlusterna \u00f6kar<br\/>Om din konstruktion \u00e4r k\u00e4nslig b\u00f6r du r\u00e4kna med att prestandan blir n\u00e5got s\u00e4mre \u00e4n vad de teoretiska ber\u00e4kningarna visar.<\/p> <\/li><li class=\"schema-how-to-step\" id=\"how-to-step-1774453635396\"><strong class=\"schema-how-to-step-name\">4. Placera signallagren n\u00e4ra referensplanen<\/strong> <p class=\"schema-how-to-step-text\">Detta minskar k\u00e4nsligheten f\u00f6r variationer i Er och f\u00f6rb\u00e4ttrar stabiliteten i returv\u00e4gen.<br\/>Grundl\u00e4ggande metoder f\u00f6r stapling beskrivs i <strong><a href=\"https:\/\/www.han-sphere.com\/blog\/news\/fr4-pcb-stackup-design-guide\/\">Guide till utformning av FR4-kretskortets skiktuppbyggnad<\/a><\/strong>.<\/p> <\/li><li class=\"schema-how-to-step\" id=\"how-to-step-1774453661721\"><strong class=\"schema-how-to-step-name\">5. Att veta n\u00e4r FR4 inte r\u00e4cker till<\/strong> <p class=\"schema-how-to-step-text\">At some point, tweaking Er assumptions won\u2019t fix the problem.<br\/>Om du ser:<br\/>f\u00f6r stor ins\u00e4ttningsf\u00f6rlust<br\/>instabil impedans<br\/>str\u00e4nga RF-krav<br\/>Det kanske \u00e4r dags att byta till ett material med l\u00e5ga f\u00f6rluster.<br\/>See <strong><a href=\"https:\/\/www.han-sphere.com\/blog\/news\/low-loss-pcb-materials-rf-microwave-circuits\/\">Kretskortmaterial med l\u00e5ga f\u00f6rluster f\u00f6r RF- och mikrov\u00e5gskretsar<\/a><\/strong>.<\/p> <\/li><\/ol><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"521\" src=\"http:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/03\/FR4-PCB-11.jpg\" alt=\"FR4-kretskort\" class=\"wp-image-514\" srcset=\"https:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/03\/FR4-PCB-11.jpg 600w, https:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/03\/FR4-PCB-11-300x261.jpg 300w, https:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/03\/FR4-PCB-11-14x12.jpg 14w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\">Praktiska tips fr\u00e5n verkliga projekt<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">N\u00e5gra saker som ofta \u00f6verraskar folk:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>The Er in simulation tools often doesn\u2019t match fabricated boards<\/li>\n\n\n\n<li>Olika leverant\u00f6rer kan ge m\u00e4rkbart olika resultat<\/li>\n\n\n\n<li>Prepreg and core materials don\u2019t behave identically<\/li>\n\n\n\n<li>Kopparens ytr\u00e5het kan p\u00e5verka det effektiva dielektriska beteendet<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">S\u00e5 betrakta Er som en <strong>intervall<\/strong>, inte en konstant.<\/p>\n\n\n\n<h1 class=\"wp-block-heading\">Slutsats<\/h1>\n\n\n\n<p class=\"wp-block-paragraph\">FR4 dielectric constant is not fixed\u2014it varies with frequency, material composition, and even layout conditions.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For low-speed designs, this variation usually doesn\u2019t matter.<br>N\u00e4r det g\u00e4ller h\u00f6ghastighetskretsar eller RF-kretsar p\u00e5verkar det direkt impedansen och signalintegriteten.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Det viktigaste \u00e4r inte att str\u00e4va efter ett perfekt Er-v\u00e4rde, utan att utforma kretsen utifr\u00e5n realistiska antaganden och samr\u00e5da med din kretskortstillverkare.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">FAQ<\/h2>\n\n\n\n<div class=\"schema-faq wp-block-yoast-faq-block\"><div class=\"schema-faq-section\" id=\"faq-question-1774453753561\"><strong class=\"schema-faq-question\">\u00c4r FR4:s dielektricitetskonstant konstant?<\/strong> <p class=\"schema-faq-answer\">Nej. Det beror p\u00e5 frekvensen, materialets sammans\u00e4ttning och tillverkningsprocessen.<\/p> <\/div> <div class=\"schema-faq-section\" id=\"faq-question-1774453858375\"><strong class=\"schema-faq-question\">Vad \u00e4r det typiska Er-v\u00e4rdet f\u00f6r FR4?<\/strong> <p class=\"schema-faq-answer\">Usually quoted around 4.2\u20134.6, but the actual value depends on frequency and laminate type.<\/p> <\/div> <div class=\"schema-faq-section\" id=\"faq-question-1774453901118\"><strong class=\"schema-faq-question\">Varf\u00f6r minskar Er vid h\u00f6gre frekvenser?<\/strong> <p class=\"schema-faq-answer\">Eftersom polariseringsmekanismerna i materialet blir mindre effektiva n\u00e4r frekvensen \u00f6kar.<\/p> <\/div> <div class=\"schema-faq-section\" id=\"faq-question-1774453912383\"><strong class=\"schema-faq-question\">P\u00e5verkar Er-variationen impedansen?<\/strong> <p class=\"schema-faq-answer\">Ja. \u00c4ven sm\u00e5 f\u00f6r\u00e4ndringar i Er kan p\u00e5verka den kontrollerade impedansen och signalintegriteten.<\/p> <\/div> <div class=\"schema-faq-section\" id=\"faq-question-1774453990064\"><strong class=\"schema-faq-question\">N\u00e4r b\u00f6r jag sluta anv\u00e4nda FR4?<\/strong> <p class=\"schema-faq-answer\">Ja. \u00c4ven sm\u00e5 f\u00f6r\u00e4ndringar i Er kan p\u00e5verka den kontrollerade impedansen och signalintegriteten.<\/p> <\/div> <\/div>","protected":false},"excerpt":{"rendered":"<p>Dielektricitetskonstanten (Er) f\u00f6r FR4 \u00e4r inte ett fast v\u00e4rde. Den varierar beroende p\u00e5 frekvens, hartssammans\u00e4ttning och tillverkningsprocess. Denna variation p\u00e5verkar impedanskontrollen och signalintegriteten, s\u00e4rskilt i h\u00f6ghastighets- och RF-konstruktioner. I den h\u00e4r artikeln f\u00f6rklaras hur Er f\u00f6r\u00e4ndras med frekvensen och vad ingenj\u00f6rer b\u00f6r beakta vid konstruktion av FR4-baserade kretskort.<\/p>","protected":false},"author":1,"featured_media":511,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":"","footnotes":""},"categories":[4],"tags":[44],"class_list":["post-553","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news","tag-fr4"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>FR4 Dielectric Constant (Er) vs Frequency Explained - HanSphere<\/title>\n<meta name=\"description\" content=\"Understand how the dielectric constant (Er) of FR4 changes with frequency and how it affects impedance and signal integrity in PCB design.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.han-sphere.com\/sv\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/\" \/>\n<meta property=\"og:locale\" content=\"sv_SE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"FR4 Dielectric Constant (Er) vs Frequency Explained - HanSphere\" \/>\n<meta property=\"og:description\" content=\"Understand how the dielectric constant (Er) of FR4 changes with frequency and how it affects impedance and signal integrity in PCB design.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.han-sphere.com\/sv\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/\" \/>\n<meta property=\"og:site_name\" content=\"hansphere\" \/>\n<meta property=\"article:published_time\" content=\"2026-03-29T00:33:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/03\/FR4-PCB-8.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"600\" \/>\n\t<meta property=\"og:image:height\" content=\"498\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"hansphere01\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Skriven av\" \/>\n\t<meta name=\"twitter:data1\" content=\"hansphere01\" \/>\n\t<meta name=\"twitter:label2\" content=\"Ber\u00e4knad l\u00e4stid\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minuter\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":[\"WebPage\",\"FAQPage\"],\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/\",\"url\":\"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/\",\"name\":\"FR4 Dielectric Constant (Er) vs Frequency Explained - HanSphere\",\"isPartOf\":{\"@id\":\"https:\/\/www.han-sphere.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/03\/FR4-PCB-8.jpg\",\"datePublished\":\"2026-03-29T00:33:00+00:00\",\"author\":{\"@id\":\"https:\/\/www.han-sphere.com\/#\/schema\/person\/a8f2356806898d33a9f431801140e422\"},\"description\":\"Understand how the dielectric constant (Er) of FR4 changes with frequency and how it affects impedance and signal integrity in PCB design.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#breadcrumb\"},\"mainEntity\":[{\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#faq-question-1774453753561\"},{\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#faq-question-1774453858375\"},{\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#faq-question-1774453901118\"},{\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#faq-question-1774453912383\"},{\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#faq-question-1774453990064\"}],\"inLanguage\":\"sv-SE\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"sv-SE\",\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#primaryimage\",\"url\":\"https:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/03\/FR4-PCB-8.jpg\",\"contentUrl\":\"https:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/03\/FR4-PCB-8.jpg\",\"width\":600,\"height\":498,\"caption\":\"FR4 PCB\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.han-sphere.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"FR4 Dielectric Constant (Er) vs Frequency Explained\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.han-sphere.com\/#website\",\"url\":\"https:\/\/www.han-sphere.com\/\",\"name\":\"hansphere\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.han-sphere.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"sv-SE\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.han-sphere.com\/#\/schema\/person\/a8f2356806898d33a9f431801140e422\",\"name\":\"hansphere01\",\"sameAs\":[\"http:\/\/www.han-sphere.com\/\"],\"url\":\"https:\/\/www.han-sphere.com\/sv\/author\/hansphere01\/\"},{\"@type\":\"Question\",\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#faq-question-1774453753561\",\"position\":1,\"url\":\"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#faq-question-1774453753561\",\"name\":\"Is FR4 dielectric constant constant?\",\"answerCount\":1,\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No. It varies with frequency, material composition, and manufacturing process.\",\"inLanguage\":\"sv-SE\"},\"inLanguage\":\"sv-SE\"},{\"@type\":\"Question\",\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#faq-question-1774453858375\",\"position\":2,\"url\":\"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#faq-question-1774453858375\",\"name\":\"What is the typical Er value of FR4?\",\"answerCount\":1,\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Usually quoted around 4.2\u20134.6, but the actual value depends on frequency and laminate type.\",\"inLanguage\":\"sv-SE\"},\"inLanguage\":\"sv-SE\"},{\"@type\":\"Question\",\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#faq-question-1774453901118\",\"position\":3,\"url\":\"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#faq-question-1774453901118\",\"name\":\"Why does Er decrease at higher frequencies?\",\"answerCount\":1,\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Because polarization mechanisms in the material become less effective as frequency increases.\",\"inLanguage\":\"sv-SE\"},\"inLanguage\":\"sv-SE\"},{\"@type\":\"Question\",\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#faq-question-1774453912383\",\"position\":4,\"url\":\"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#faq-question-1774453912383\",\"name\":\"Does Er variation affect impedance?\",\"answerCount\":1,\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. Even small changes in Er can affect controlled impedance and signal integrity.\",\"inLanguage\":\"sv-SE\"},\"inLanguage\":\"sv-SE\"},{\"@type\":\"Question\",\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#faq-question-1774453990064\",\"position\":5,\"url\":\"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#faq-question-1774453990064\",\"name\":\"When should I stop using FR4?\",\"answerCount\":1,\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. Even small changes in Er can affect controlled impedance and signal integrity.\",\"inLanguage\":\"sv-SE\"},\"inLanguage\":\"sv-SE\"},{\"@type\":\"HowTo\",\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#howto-1\",\"name\":\"FR4 Dielectric Constant (Er) vs Frequency Explained\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/\"},\"description\":\"You don\u2019t need perfect data\u2014you need realistic assumptions.\",\"step\":[{\"@type\":\"HowToStep\",\"url\":\"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#how-to-step-1774453565242\",\"name\":\"1. Use Manufacturer Stackup Data\",\"itemListElement\":[{\"@type\":\"HowToDirection\",\"text\":\"Don\u2019t rely on generic Er values.<br\/>Use:<br\/>laminate datasheets<br\/>impedance tables from your PCB vendor<br\/>They\u2019re closer to actual fabrication conditions.\"}]},{\"@type\":\"HowToStep\",\"url\":\"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#how-to-step-1774453593981\",\"name\":\"2. Design Around Target Impedance, Not Nominal Er\",\"itemListElement\":[{\"@type\":\"HowToDirection\",\"text\":\"Instead of focusing on Er directly:<br\/>define target impedance (e.g., 50\u03a9, 100\u03a9 diff)<br\/>adjust trace width and spacing accordingly<br\/>Let the manufacturer help tune the stackup.\"}]},{\"@type\":\"HowToStep\",\"url\":\"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#how-to-step-1774453621498\",\"name\":\"3. Be Conservative at Higher Frequencies\",\"itemListElement\":[{\"@type\":\"HowToDirection\",\"text\":\"As frequency increases:<br\/>uncertainty increases<br\/>loss increases<br\/>If your design is sensitive, assume slightly worse performance than ideal calculations.\"}]},{\"@type\":\"HowToStep\",\"url\":\"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#how-to-step-1774453635396\",\"name\":\"4. Keep Signal Layers Close to Reference Planes\",\"itemListElement\":[{\"@type\":\"HowToDirection\",\"text\":\"This reduces sensitivity to Er variation and improves return path stability.<br\/>Basic stackup practices are covered in <strong><a href=\\\"https:\/\/www.han-sphere.com\/blog\/news\/fr4-pcb-stackup-design-guide\/\\\">FR4 PCB Stackup Design Guide<\/a><\/strong>.\"}]},{\"@type\":\"HowToStep\",\"url\":\"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#how-to-step-1774453661721\",\"name\":\"5. Know When FR4 Is Not Enough\",\"itemListElement\":[{\"@type\":\"HowToDirection\",\"text\":\"At some point, tweaking Er assumptions won\u2019t fix the problem.<br\/>If you see:<br\/>excessive insertion loss<br\/>unstable impedance<br\/>tight RF requirements<br\/>it may be time to move to a low-loss material.<br\/>See <strong><a href=\\\"https:\/\/www.han-sphere.com\/blog\/news\/low-loss-pcb-materials-rf-microwave-circuits\/\\\">Low-Loss PCB Materials for RF and Microwave Circuits<\/a><\/strong>.\"}]}],\"inLanguage\":\"sv-SE\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"F\u00f6rklaring av FR4:s dielektricitetskonstant (Er) i f\u00f6rh\u00e5llande till frekvensen \u2013 HanSphere","description":"F\u00f6rst\u00e5 hur dielektricitetskonstanten (Er) hos FR4 varierar med frekvensen och hur detta p\u00e5verkar impedansen och signalintegriteten vid kretskortskonstruktion.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.han-sphere.com\/sv\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/","og_locale":"sv_SE","og_type":"article","og_title":"FR4 Dielectric Constant (Er) vs Frequency Explained - HanSphere","og_description":"Understand how the dielectric constant (Er) of FR4 changes with frequency and how it affects impedance and signal integrity in PCB design.","og_url":"https:\/\/www.han-sphere.com\/sv\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/","og_site_name":"hansphere","article_published_time":"2026-03-29T00:33:00+00:00","og_image":[{"width":600,"height":498,"url":"https:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/03\/FR4-PCB-8.jpg","type":"image\/jpeg"}],"author":"hansphere01","twitter_card":"summary_large_image","twitter_misc":{"Skriven av":"hansphere01","Ber\u00e4knad l\u00e4stid":"5 minuter"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":["WebPage","FAQPage"],"@id":"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/","url":"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/","name":"F\u00f6rklaring av FR4:s dielektricitetskonstant (Er) i f\u00f6rh\u00e5llande till frekvensen \u2013 HanSphere","isPartOf":{"@id":"https:\/\/www.han-sphere.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#primaryimage"},"image":{"@id":"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#primaryimage"},"thumbnailUrl":"https:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/03\/FR4-PCB-8.jpg","datePublished":"2026-03-29T00:33:00+00:00","author":{"@id":"https:\/\/www.han-sphere.com\/#\/schema\/person\/a8f2356806898d33a9f431801140e422"},"description":"F\u00f6rst\u00e5 hur dielektricitetskonstanten (Er) hos FR4 varierar med frekvensen och hur detta p\u00e5verkar impedansen och signalintegriteten vid kretskortskonstruktion.","breadcrumb":{"@id":"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#breadcrumb"},"mainEntity":[{"@id":"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#faq-question-1774453753561"},{"@id":"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#faq-question-1774453858375"},{"@id":"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#faq-question-1774453901118"},{"@id":"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#faq-question-1774453912383"},{"@id":"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#faq-question-1774453990064"}],"inLanguage":"sv-SE","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/"]}]},{"@type":"ImageObject","inLanguage":"sv-SE","@id":"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#primaryimage","url":"https:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/03\/FR4-PCB-8.jpg","contentUrl":"https:\/\/www.han-sphere.com\/wp-content\/uploads\/2026\/03\/FR4-PCB-8.jpg","width":600,"height":498,"caption":"FR4 PCB"},{"@type":"BreadcrumbList","@id":"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.han-sphere.com\/"},{"@type":"ListItem","position":2,"name":"FR4 Dielectric Constant (Er) vs Frequency Explained"}]},{"@type":"WebSite","@id":"https:\/\/www.han-sphere.com\/#website","url":"https:\/\/www.han-sphere.com\/","name":"hansphere","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.han-sphere.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"sv-SE"},{"@type":"Person","@id":"https:\/\/www.han-sphere.com\/#\/schema\/person\/a8f2356806898d33a9f431801140e422","name":"hansphere01","sameAs":["http:\/\/www.han-sphere.com\/"],"url":"https:\/\/www.han-sphere.com\/sv\/author\/hansphere01\/"},{"@type":"Question","@id":"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#faq-question-1774453753561","position":1,"url":"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#faq-question-1774453753561","name":"\u00c4r FR4:s dielektricitetskonstant konstant?","answerCount":1,"acceptedAnswer":{"@type":"Answer","text":"No. It varies with frequency, material composition, and manufacturing process.","inLanguage":"sv-SE"},"inLanguage":"sv-SE"},{"@type":"Question","@id":"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#faq-question-1774453858375","position":2,"url":"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#faq-question-1774453858375","name":"Vad \u00e4r det typiska Er-v\u00e4rdet f\u00f6r FR4?","answerCount":1,"acceptedAnswer":{"@type":"Answer","text":"Usually quoted around 4.2\u20134.6, but the actual value depends on frequency and laminate type.","inLanguage":"sv-SE"},"inLanguage":"sv-SE"},{"@type":"Question","@id":"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#faq-question-1774453901118","position":3,"url":"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#faq-question-1774453901118","name":"Varf\u00f6r minskar Er vid h\u00f6gre frekvenser?","answerCount":1,"acceptedAnswer":{"@type":"Answer","text":"Because polarization mechanisms in the material become less effective as frequency increases.","inLanguage":"sv-SE"},"inLanguage":"sv-SE"},{"@type":"Question","@id":"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#faq-question-1774453912383","position":4,"url":"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#faq-question-1774453912383","name":"P\u00e5verkar Er-variationen impedansen?","answerCount":1,"acceptedAnswer":{"@type":"Answer","text":"Yes. Even small changes in Er can affect controlled impedance and signal integrity.","inLanguage":"sv-SE"},"inLanguage":"sv-SE"},{"@type":"Question","@id":"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#faq-question-1774453990064","position":5,"url":"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#faq-question-1774453990064","name":"N\u00e4r b\u00f6r jag sluta anv\u00e4nda FR4?","answerCount":1,"acceptedAnswer":{"@type":"Answer","text":"Yes. Even small changes in Er can affect controlled impedance and signal integrity.","inLanguage":"sv-SE"},"inLanguage":"sv-SE"},{"@type":"HowTo","@id":"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#howto-1","name":"F\u00f6rklaring av FR4:s dielektricitetskonstant (Er) i f\u00f6rh\u00e5llande till frekvensen","mainEntityOfPage":{"@id":"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/"},"description":"You don\u2019t need perfect data\u2014you need realistic assumptions.","step":[{"@type":"HowToStep","url":"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#how-to-step-1774453565242","name":"1. Use Manufacturer Stackup Data","itemListElement":[{"@type":"HowToDirection","text":"Don\u2019t rely on generic Er values.<br\/>Use:<br\/>laminate datasheets<br\/>impedance tables from your PCB vendor<br\/>They\u2019re closer to actual fabrication conditions."}]},{"@type":"HowToStep","url":"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#how-to-step-1774453593981","name":"2. Design Around Target Impedance, Not Nominal Er","itemListElement":[{"@type":"HowToDirection","text":"Instead of focusing on Er directly:<br\/>define target impedance (e.g., 50\u03a9, 100\u03a9 diff)<br\/>adjust trace width and spacing accordingly<br\/>Let the manufacturer help tune the stackup."}]},{"@type":"HowToStep","url":"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#how-to-step-1774453621498","name":"3. Be Conservative at Higher Frequencies","itemListElement":[{"@type":"HowToDirection","text":"As frequency increases:<br\/>uncertainty increases<br\/>loss increases<br\/>If your design is sensitive, assume slightly worse performance than ideal calculations."}]},{"@type":"HowToStep","url":"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#how-to-step-1774453635396","name":"4. Keep Signal Layers Close to Reference Planes","itemListElement":[{"@type":"HowToDirection","text":"This reduces sensitivity to Er variation and improves return path stability.<br\/>Basic stackup practices are covered in <strong><a href=\"https:\/\/www.han-sphere.com\/blog\/news\/fr4-pcb-stackup-design-guide\/\">FR4 PCB Stackup Design Guide<\/a><\/strong>."}]},{"@type":"HowToStep","url":"https:\/\/www.han-sphere.com\/blog\/news\/fr4-dielectric-constant-er-vs-frequency\/#how-to-step-1774453661721","name":"5. Know When FR4 Is Not Enough","itemListElement":[{"@type":"HowToDirection","text":"At some point, tweaking Er assumptions won\u2019t fix the problem.<br\/>If you see:<br\/>excessive insertion loss<br\/>unstable impedance<br\/>tight RF requirements<br\/>it may be time to move to a low-loss material.<br\/>See <strong><a href=\"https:\/\/www.han-sphere.com\/blog\/news\/low-loss-pcb-materials-rf-microwave-circuits\/\">Low-Loss PCB Materials for RF and Microwave Circuits<\/a><\/strong>."}]}],"inLanguage":"sv-SE"}]}},"_links":{"self":[{"href":"https:\/\/www.han-sphere.com\/sv\/wp-json\/wp\/v2\/posts\/553","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.han-sphere.com\/sv\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.han-sphere.com\/sv\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.han-sphere.com\/sv\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.han-sphere.com\/sv\/wp-json\/wp\/v2\/comments?post=553"}],"version-history":[{"count":1,"href":"https:\/\/www.han-sphere.com\/sv\/wp-json\/wp\/v2\/posts\/553\/revisions"}],"predecessor-version":[{"id":554,"href":"https:\/\/www.han-sphere.com\/sv\/wp-json\/wp\/v2\/posts\/553\/revisions\/554"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.han-sphere.com\/sv\/wp-json\/wp\/v2\/media\/511"}],"wp:attachment":[{"href":"https:\/\/www.han-sphere.com\/sv\/wp-json\/wp\/v2\/media?parent=553"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.han-sphere.com\/sv\/wp-json\/wp\/v2\/categories?post=553"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.han-sphere.com\/sv\/wp-json\/wp\/v2\/tags?post=553"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}