PCB Design Tools

PCB Trace Width Calculator

This PCB Trace Width Calculator helps engineers determine the optimal copper trace width based on current, copper weight, temperature rise, and layer type. Using IPC-2221 guidelines, this tool helps improve power integrity, prevent overheating, and ensure reliable PCB performance.

More PCB Tools All Tools Gold Fingers PI Calculator PCB Impedance Calculator Via Current Calculator Copper Weight Converter Flex Bend Radius Calculator
Input parameters
A
Calculation results
Internal Layers (IPC-2221)
— mil
Required Trace Width (W)
External Layers in Air
— mil
Required Trace Width (W)
MetricInternalExternal
Required Trace Width (W)— mil— mil
Resistance (R)— Ω— Ω
Voltage Drop— V— V
Power Loss— W— W

* Internal layer results use IPC-2221 internal constants (k=0.024). External layer results use external constants (k=0.048). Resistance and power loss calculations assume copper resistivity of 1.72×10⁻⁸ Ω·m at ambient temperature with temperature coefficient 0.00393/°C.

Formula
Step 1 — Calculate cross-sectional Area (mil²):
A = ( I K × TRiseb ) 1/c
Step 2 — Calculate Trace Width (mil):
W = A t × 1.378

For IPC-2221 internal layers:

k = 0.024,  b = 0.44,  c = 0.725

For IPC-2221 external layers:

k = 0.048,  b = 0.44,  c = 0.725

where k, b, and c are constants resulting from curve fitting to the IPC-2221 curves.

Common values:

Thickness: 1 oz (= 1.378 mil)
Ambient: 25 °C
Temp rise: 10 °C

Resistance formula:
R = ρ × L × [1 + α(T − 20°C)] W × t

ρ = 1.72×10⁻⁸ Ω·m (copper resistivity at 20°C)
α = 0.00393 /°C (temperature coefficient)
T = ambient temperature (°C)
L = trace length, W = width, t = thickness