How the calculation works
The PI stiffener is glued to the back of the FPC gold finger area to bring the total thickness up to the connector spec. The key insight is that in the gold finger area, the top coverlay is absent (fingers must be exposed), and optionally the back copper may also be absent. So the effective FPC thickness in the gold finger zone is less than the base FPC thickness, and the PI must make up the difference.
Calculation formulas
-
Copper on back — YES: Only the top coverlay is removed.
PI = Connector target − (FPC base − 1× Coverlay thickness)
-
Copper on back — NO: Top coverlay AND the absent back copper layer are both removed.
PI = Connector target − (FPC base − 1× Coverlay − 1× Copper thickness)
How layers affect the result:
Adding a 2nd layer adds another copper layer (0.012 mm) and an additional adhesive layer (0.015 mm) to the FPC base. This raises the FPC thickness, which reduces the required PI stiffener.
Example — 2 layers, 0.11 mm base, no copper on back
FPC base = 0.11 mm + 0.012 (extra Cu) + 0.015 (extra adhesive) = 0.137 mm
Effective zone = 0.137 − 0.0275 (coverlay) − 0.012 (no back Cu) = 0.0975 mm
PI = 0.30 − 0.0975 = 0.2025 mm → recommend 0.25 mm
Standard layer thicknesses
- Copper H oz (0.5 oz): 0.012 mm
- Yellow / Black coverlay: 0.0275 mm
- White coverlay: 0.0300 mm
- PI dielectric 25 µm: 0.025 mm
- PI dielectric 50 µm: 0.050 mm
- Transparent dielectric: 0.025 mm
- Adhesive (per bond layer): 0.015 mm
Available standard PI stiffener thicknesses
Always round up to the next standard size to guarantee connector fit.
0.10 mm
0.15 mm
0.20 mm
0.25 mm
0.30 mm
0.40 mm
0.50 mm
0.75 mm
1.00 mm