| Metrisch | Enkele via | 2 Doorgangen |
|---|---|---|
| Maximale stroom bij toegestane stijging | — A | — A |
| Stroom per Via | — A | — A |
| Weerstand (via) | — mΩ | — mΩ |
| Spanningsval | — mV | — mV |
| Stroomuitval (totaal) | — W | — W |
* Via barrel is modeled as an unrolled copper trace (circumference × plating thickness), using IPC-2221 external-layer constants. This is a practical engineering estimate — verify against your fab's actual plating tolerance, and confirm final via count and placement with your manufacturer for high-current designs.
k = 0,048, b = 0,44, c = 0,725
D = diameter van het afgewerkte gat, t = dikte van de beplating, beide in mil. A is the barrel's unrolled cross-sectional area in mil².
Minimum volgens IPC-6012: 25 µm (~1 mijl)
Zwaar koper / hoge stroomsterkte: 50–75 µm
ρ = 1.72×10⁻⁸ Ω·m (copper resistivity)
L = via-lengte (dikte van de printplaat)
Parallelle via’s: de weerstand wordt gedeeld door N, de stroom wordt gedeeld door N
We gebruiken cookies om uw ervaring te verbeteren. Zie onze Privacybeleid.