Rogers, Taconic and PTFE laminates from 1 GHz to 110 GHz — stocked in-house, processed in-house, and TDR + VNA verified before every shipment.
A high-frequency PCB is built on purpose-designed low-loss laminate — Rogers, Taconic, PTFE or ceramic-filled PTFE — instead of standard FR4. The laminate choice is not a preference. At frequencies above 1 GHz, standard FR4 introduces signal loss and impedance variance that degrades system performance in ways that cannot be compensated by circuit design.
At 10 GHz, a trace on Rogers 4350B has approximately 5× less loss than the same trace on FR4. At 77 GHz — used for automotive radar — FR4 is not a usable transmission medium. The physics of high-frequency signal propagation make laminate selection a critical design decision, not a procurement variable.
Our RF engineers specify the right laminate for your frequency band, thermal environment and cost target — then fabricate, verify with TDR and optionally with VNA before shipment.
Get RF PCB Quote →
Vanwege de fysische aspecten van diëlektrische verliezen en variaties in de diëlektrische constante (Dk) is de keuze van het laminaat de belangrijkste beslissing bij het ontwerpen van RF-printplaten.
FR4's loss tangent (tan δ) of 0.020–0.025 causes signal attenuation of 1–3 dB/cm at 10 GHz. Rogers 4350B has tan δ = 0.0037 — approximately 6× lower loss at the same frequency and geometry. For a 5G base station power amplifier, this difference directly translates to efficiency, thermal dissipation and operating cost at scale.
tan δ FR4 = 0.022 · Rogers 4350B = 0.0037 · 6× less attenuationFR4's dielectric constant varies from 4.2 to 4.8 between suppliers and even between production lots from the same supplier. A 50 Ω trace designed to nominal Dk = 4.4 can be 44 Ω or 57 Ω on a different FR4 lot — before fabrication tolerance is even considered. Rogers 4350B has Dk = 3.48 ±0.05 — tight enough to design to with confidence.
FR4 Dk variance ±0.3 · Rogers 4350B Dk = 3.48 ±0.05Most RF + digital mixed designs do not need Rogers on every layer. Outer layers handling RF traces use Rogers or PTFE for signal performance. Inner digital layers handling clocks, power and data buses use standard FR4 at standard cost. Our hybrid stackup design service specifies which layers need low-loss laminate and which do not — optimising performance per dollar.
Rogers outer layers · FR4 inner layers · hybrid stackup · cost optimisedAlle RF-laminaten zijn uit eigen voorraad leverbaar. Bij elke bestelling van producten met gecontroleerde impedantie wordt een TDR-impedantierapport meegeleverd. VNA-S-parameters zijn op aanvraag verkrijgbaar.
| Maximale bedrijfsfrequentie | Tot 110 GHz (Rogers 3003C / PTFE) |
| Impedantietolerantie | ±5% TDR verified (±3% on precision orders) |
| RF-laminaten | Rogers 4350B · RO4003C · RO3003C · Taconic TLY · PTFE |
| Aantal lagen | 2 – 30 layers |
| Min. Spatie / Spatie | 2.5 / 2.5 mil (RF: ±0.5 mil tolerance) |
| Oppervlakteafwerking | ENIG · ENEPIG · Electrolytic Hard Gold |
| Uithollingsfrezen | Waveguide integration · connector pockets |
| Achterboor | Door het verwijderen van stubs bij digitale lagen met hoge snelheid |
| Controle | TDR standard · VNA S-parameters on request |
| Doorlooptijd van prototypes | 48h express · 5 days standard |
Bij de productie van RF-printplaten worden strengere procestoleranties gehanteerd en worden RF-specifieke controlestappen uitgevoerd die bij de standaardproductie van printplaten niet voorkomen.
Rogers, Taconic or PTFE laminate is selected per Dk, tan δ and CTE requirements. Incoming Dk is verified against CoC before production begins.
Trace width is held to ±0.5 mil (vs ±1 mil on FR4) using optimised photolithography parameters. Verified by SEM measurement on every lot.
Met precisie-CNC-frezen worden golfgeleiderovergangen en aansluitingsuitsparingen voor mmWave-printplaten vervaardigd. Laserboren voor microvia’s in hybride opbouw.
De impedantie van elke printplaat wordt gemeten met behulp van de TDR-methode. Voor alle printplaten is een VNA-karakterisering van de S-parameters (invoegverlies versus frequentie) beschikbaar.
Toepassingen waarbij standaard FR4 tot onaanvaardbaar signaalverlies of impedantievariatie leidt.
Rogers/PTFE boards for 5G NR sub-6 GHz and mmWave radio units — power amplifiers and antenna feeds.
77 GHz ADAS radar front-ends on Rogers 4350B — forward collision, lane departure and blind-spot systems.
6–86 GHz point-to-point backhaul radios used in mobile network infrastructure.
Breedband-RF-printplaten voor ESM-, storings- en signaalinlichtingensystemen over frequentiebereiken van meerdere octaven.
Ka/Ku-band zendontvangerkaarten voor de elektronica van LEO/GEO-satellietpayloads en VSAT-terminals.
RF-front-ends met lage fase-ruis voor testapparatuur die werkt van DC tot 110 GHz.
RF-printplaten in het GHz-bereik voor MRI-gradiëntspoelstuurcircuits en medische radar (detectie van ademhaling en vitale functies).
60 GHz- en 77 GHz-printplaten voor industriële aanwezigheidsdetectie, niveaumeting en gebarendetectie.
Optical inspection confirms copper is present. TDR confirms impedance is correct. VNA confirms insertion loss meets your link budget. For high-frequency boards, we apply all three — because every unverified PCB variable becomes a variable in your RF system.
Real RF PCB challenges — material expertise and process precision delivered.
8-layer Rogers 4350B, 128 antenna feed lines TDR-verified ±4.2%, ENIG, -40°C to +85°C, IATF 16949 documentation.
Alle antenne-uitgangen voldoen aan de specificaties. Bij de test van het RF-systeem werd de simulatie met +0,8 dB antenneversterking overtroffen. De FAI volgens IATF 16949 werd bij de eerste indiening goedgekeurd.
12-laags hybride Rogers 4350B / FR4, 64T64R massive MIMO, met holle freesbewerking vervaardigde openingen voor patch-antennes, 0,5 mm BGA-fan-out voor beamforming-IC’s.
De test van het RF-systeem overtrof de simulatie. Tijdige levering gedurende drie opeenvolgende productiekwartalen. De klant heeft HanSphere aangewezen als voorkeursleverancier voor het 39 GHz-programma.
20-laags Rogers 3003C, met holtes gefreesde golfgeleiderovergangen, elektrolytisch hardgoud op RF-interfaces, per printplaat gekarakteriseerd met een VNA.
Invoegverlies binnen 0,3 dB van de simulatie bij 67 GHz. Alle printplaten worden geleverd met individuele VNA-gegevensbestanden. 100% slaagt bij instrumentkalibratie zonder RF-herstelwerkzaamheden.
Technische vragen over de keuze van RF-laminaat, impedantieregeling en fabricage.
We hold in-house stock of: Rogers 4350B (Dk 3.48, tan δ 0.0037), RO4003C (Dk 3.55, tan δ 0.0027), RO3003C (Dk 3.00, tan δ 0.0013), Taconic TLY (Dk 2.17, tan δ 0.0009), Taconic RF-35 (Dk 3.50, tan δ 0.0018), and PTFE-based laminates for frequencies above 40 GHz. Material CoC with Dk and tan δ per lot is supplied with every order.
Our standard RF impedance tolerance is ±5%, verified by TDR measurement and reported per board. For precision applications (test instruments, VNA boards, precision phase-matched lines), ±3% tolerance is available — this requires ±0.5 mil trace width control and Dk-verified laminate selection. Specify your required tolerance at enquiry stage.
Yes — full 2-port VNA S-parameter measurements (S11, S21 insertion loss vs frequency) are available on all boards as an optional service. The measurement data is supplied as Touchstone (.s2p) files and can be imported directly into your RF simulation software for correlation to design intent. Specify VNA measurement at enquiry stage.
Our standard Rogers 4350B and RO4003C process supports applications to approximately 40 GHz. For W-band (75–110 GHz) applications, we use Rogers RO3003C or PTFE-based laminates with cavity milling for waveguide integration. The practical upper limit depends on laminate choice, copper surface roughness at mmWave frequencies, and connector interface geometry.
Bij een hybride opbouw wordt gebruikgemaakt van RF-laminaat met lage verliezen (Rogers, PTFE) op de buitenste lagen, waar de RF-sporen zijn aangelegd, en van standaard FR4- of high-Tg-laminaat op de binnenste lagen voor digitale stroom- en datasignalen. Dit zorgt voor goede RF-prestaties op de plaatsen waar de signaalkwaliteit van belang is (buitenste RF-sporen), terwijl de kosten aanzienlijk lager uitvallen dan bij een constructie die volledig uit Rogers-materiaal bestaat. Onze RF-ingenieurs ontwerpen regelmatig hybride opbouwen voor 5G- en ADAS-radartoepassingen.
Yes — CNC cavity milling is a standard service for mmWave boards requiring recessed connector launch areas, waveguide transitions and heat spreader pockets. Cavity depth tolerance is ±0.05 mm, wall verticality ±2°. Cavity drawings should be provided as a separate mechanical layer in the Gerber/ODB++ package. Photographs and dimensional inspection reports are available on cavity lots.
Stuur ons uw Gerber-bestanden en specificaties voor de laagopbouw. Onze RF-ingenieurs beoordelen binnen 8 uur de keuze van het laminaat, de geometrie van de printbanen en de plaatsing van de via’s.
Vul hieronder de gegevens in en we nemen zo snel mogelijk contact met u op.
We gebruiken cookies om uw ervaring te verbeteren. Zie onze Privacybeleid.