Rogers, Taconic and PTFE laminates from 1 GHz to 110 GHz — stocked in-house, processed in-house, and TDR + VNA verified before every shipment.
A high-frequency PCB is built on purpose-designed low-loss laminate — Rogers, Taconic, PTFE or ceramic-filled PTFE — instead of standard FR4. The laminate choice is not a preference. At frequencies above 1 GHz, standard FR4 introduces signal loss and impedance variance that degrades system performance in ways that cannot be compensated by circuit design.
At 10 GHz, a trace on Rogers 4350B has approximately 5× less loss than the same trace on FR4. At 77 GHz — used for automotive radar — FR4 is not a usable transmission medium. The physics of high-frequency signal propagation make laminate selection a critical design decision, not a procurement variable.
Our RF engineers specify the right laminate for your frequency band, thermal environment and cost target — then fabricate, verify with TDR and optionally with VNA before shipment.
Get RF PCB Quote →
Dielektrik kaybı ve Dk değişkenliğinin fiziksel özellikleri, laminat seçimini RF PCB tasarımında alınacak en önemli karar haline getirir.
FR4's loss tangent (tan δ) of 0.020–0.025 causes signal attenuation of 1–3 dB/cm at 10 GHz. Rogers 4350B has tan δ = 0.0037 — approximately 6× lower loss at the same frequency and geometry. For a 5G base station power amplifier, this difference directly translates to efficiency, thermal dissipation and operating cost at scale.
tan δ FR4 = 0.022 · Rogers 4350B = 0.0037 · 6× less attenuationFR4's dielectric constant varies from 4.2 to 4.8 between suppliers and even between production lots from the same supplier. A 50 Ω trace designed to nominal Dk = 4.4 can be 44 Ω or 57 Ω on a different FR4 lot — before fabrication tolerance is even considered. Rogers 4350B has Dk = 3.48 ±0.05 — tight enough to design to with confidence.
FR4 Dk variance ±0.3 · Rogers 4350B Dk = 3.48 ±0.05Most RF + digital mixed designs do not need Rogers on every layer. Outer layers handling RF traces use Rogers or PTFE for signal performance. Inner digital layers handling clocks, power and data buses use standard FR4 at standard cost. Our hybrid stackup design service specifies which layers need low-loss laminate and which do not — optimising performance per dollar.
Rogers outer layers · FR4 inner layers · hybrid stackup · cost optimisedTüm RF laminatları şirketimizde stokta bulunmaktadır. Her kontrollü empedans siparişiyle birlikte TDR empedans raporu sunulmaktadır. VNA S-parametreleri talep üzerine temin edilebilir.
| Maksimum Çalışma Frekansı | 110 GHz’e kadar (Rogers 3003C / PTFE) |
| Empedans Toleransı | ±5% TDR verified (±3% on precision orders) |
| RF Laminatları | Rogers 4350B · RO4003C · RO3003C · Taconic TLY · PTFE |
| Kat Sayısı | 2 – 30 layers |
| Min. İz / Boşluk | 2.5 / 2.5 mil (RF: ±0.5 mil tolerance) |
| Yüzey İşlemi | ENIG · ENEPIG · Electrolytic Hard Gold |
| Boşluk Frezeleme | Waveguide integration · connector pockets |
| Geri Matkap | Yüksek hızlı dijital katmanlar için bağlantı kolu kaldırma yöntemi |
| Doğrulama | TDR standard · VNA S-parameters on request |
| Prototip Üretim Süresi | 48h express · 5 days standard |
RF PCB üretimi, standart PCB üretiminde bulunmayan daha sıkı proses toleransları ile RF’ye özgü doğrulama adımlarını bir araya getirir.
Rogers, Taconic or PTFE laminate is selected per Dk, tan δ and CTE requirements. Incoming Dk is verified against CoC before production begins.
Trace width is held to ±0.5 mil (vs ±1 mil on FR4) using optimised photolithography parameters. Verified by SEM measurement on every lot.
Hassas CNC frezeleme, mmWave kartları için dalga kılavuzu geçişleri ve konektör yuvaları oluşturur. Hibrit katmanlı yapılar için mikro deliklerin lazerle açılması.
Her kartın empedansı TDR ile ölçülmüştür. Tüm kartlar için VNA S-parametre karakterizasyonu (frekansa göre ekleme kaybı) mevcuttur.
Standart FR4’ün kabul edilemez sinyal kaybına veya empedans dalgalanmasına yol açtığı uygulamalar.
Rogers/PTFE boards for 5G NR sub-6 GHz and mmWave radio units — power amplifiers and antenna feeds.
77 GHz ADAS radar front-ends on Rogers 4350B — forward collision, lane departure and blind-spot systems.
6–86 GHz point-to-point backhaul radios used in mobile network infrastructure.
Birden fazla oktavlık frekans aralıklarında ESM, sinyal bozma ve sinyal istihbarat sistemleri için geniş bant RF kartları.
LEO/GEO uydularının yük elektroniği ve VSAT terminalleri için Ka/Ku bandı alıcı-verici kartları.
DC’den 110 GHz’e kadar çalışan test cihazları için düşük faz gürültülü RF ön uçları.
MRG gradyan bobin sürücüleri ve tıbbi radar (solunum/yaşam belirtileri algılama) için GHz aralığındaki RF kartları.
Endüstriyel varlık algılama, seviye ölçümü ve hareket algılama amaçlı 60 GHz ve 77 GHz kartlar.
Optical inspection confirms copper is present. TDR confirms impedance is correct. VNA confirms insertion loss meets your link budget. For high-frequency boards, we apply all three — because every unverified PCB variable becomes a variable in your RF system.
Real RF PCB challenges — material expertise and process precision delivered.
8-layer Rogers 4350B, 128 antenna feed lines TDR-verified ±4.2%, ENIG, -40°C to +85°C, IATF 16949 documentation.
Tüm antenler teknik şartnamede belirtilen değerler dahilindedir. RF sistemi testi, simülasyon sonuçlarını +0,8 dB anten kazancı ile aştı. IATF 16949 FAI, ilk sunumda kabul edildi.
12 katmanlı hibrit Rogers 4350B / FR4, 64T64R masif MIMO, oyukla işlenmiş yama anten açıklıkları, 0,5 mm BGA ışın şekillendirme IC fan-out.
RF sistem testi, simülasyon sonuçlarını aştı. Üç üretim çeyreği boyunca teslimatlar zamanında gerçekleştirildi. Müşteri, HanSphere’i 39 GHz programı için tercih edilen tedarikçi olarak onayladı.
20 katmanlı Rogers 3003C, oyukla işlenmiş dalga kılavuzu geçişleri, RF arayüzlerinde elektrolitik sert altın kaplama, her bir kart için VNA ile karakterize edilmiştir.
67 GHz'de simülasyon değerine göre 0,3 dB'lik bir sapma aralığında ekleme kaybı. Tüm kartlar, ayrı ayrı VNA veri dosyalarıyla birlikte sevk edilir. RF üzerinde herhangi bir düzeltme yapılmaksızın cihaz kalibrasyonunda 0 başarı oranı.
RF laminat seçimi, empedans kontrolü ve imalatıyla ilgili teknik sorular.
We hold in-house stock of: Rogers 4350B (Dk 3.48, tan δ 0.0037), RO4003C (Dk 3.55, tan δ 0.0027), RO3003C (Dk 3.00, tan δ 0.0013), Taconic TLY (Dk 2.17, tan δ 0.0009), Taconic RF-35 (Dk 3.50, tan δ 0.0018), and PTFE-based laminates for frequencies above 40 GHz. Material CoC with Dk and tan δ per lot is supplied with every order.
Our standard RF impedance tolerance is ±5%, verified by TDR measurement and reported per board. For precision applications (test instruments, VNA boards, precision phase-matched lines), ±3% tolerance is available — this requires ±0.5 mil trace width control and Dk-verified laminate selection. Specify your required tolerance at enquiry stage.
Yes — full 2-port VNA S-parameter measurements (S11, S21 insertion loss vs frequency) are available on all boards as an optional service. The measurement data is supplied as Touchstone (.s2p) files and can be imported directly into your RF simulation software for correlation to design intent. Specify VNA measurement at enquiry stage.
Our standard Rogers 4350B and RO4003C process supports applications to approximately 40 GHz. For W-band (75–110 GHz) applications, we use Rogers RO3003C or PTFE-based laminates with cavity milling for waveguide integration. The practical upper limit depends on laminate choice, copper surface roughness at mmWave frequencies, and connector interface geometry.
Hibrit katman yapısında, RF izlerinin geçirildiği dış katmanlarda düşük kayıplı RF laminatı (Rogers, PTFE) kullanılırken, dijital güç ve veri sinyalleri için iç katmanlarda standart FR4 veya yüksek Tg laminatı kullanılır. Bu, sinyal kalitesinin önemli olduğu yerlerde (dış RF izleri) RF performansı sağlarken, tamamen Rogers malzemesinden oluşan yapıya kıyasla maliyeti önemli ölçüde düşürür. RF mühendislerimiz, 5G ve ADAS radar uygulamaları için rutin olarak hibrit katman yapıları tasarlar.
Yes — CNC cavity milling is a standard service for mmWave boards requiring recessed connector launch areas, waveguide transitions and heat spreader pockets. Cavity depth tolerance is ±0.05 mm, wall verticality ±2°. Cavity drawings should be provided as a separate mechanical layer in the Gerber/ODB++ package. Photographs and dimensional inspection reports are available on cavity lots.
Gerber dosyalarınızı ve katman düzeni gereksinimlerinizi gönderin. RF mühendislerimiz, 8 saat içinde laminat seçimini, devre izi geometrisini ve via yerleşimini inceler.
Aşağıdaki bilgileri doldurun, kısa süre içinde size geri dönüş yapacağız.
Kullanıcı deneyiminizi iyileştirmek amacıyla çerezler kullanıyoruz. Ayrıntılar için Gizlilik Politikası.